background image

Unpacking & Installation:

 

• ALWAYS

 install equipment in a work area with adequate light and space.

 

• ONLY 

operate on a solid, level, nonskid surface that is nonflammable and away from sinks and water hazards.

 

• NEVER 

bypass, alter or modify this equipment in any way from its original condition. Doing so may create hazards 

 

  and will void warranty.

Gas & Gas Pressure:

Unpacking:

 

 

 

 

 

  

This unit is factory supplied in Natural Gas. 

This unit can be converted to L.P. gas by a licensed 

and certified gas technician. Documentation may be necessary for warranty issues. Failure to comply 

with this instruction, will void warranty. 

See the included L.P. conversion kit for gas conversion parts and instructions.

Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the  National 

Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2  as applicable 

and in accordance with local codes.

The appliance and it’s individual shutoff valve (to be supplied by user) must be disconnected  from 

the gas supply piping system during any pressure testing of that system at test pressures in excess 

of ½ psi (3.45 kPa).

These models are designed, built, and sold for commercial use only.

Instructions must be posted in a prominent location. All safety precautions must be taken in the event 

the user smells gas. Safety information can be obtained from your local gas supplier.

Unpack the 

hot plate/cookop 

immediately after receipt. Remove the gas 

hot plate/cookop 

from the crate; remove all packag-

ing on and surrounding the unit and be certain to remove all protective plastics and residues from all surfaces. Make sure that all 

parts provided including the L.P. gas conversion kit are located. Equipment must have the legs properly installed before use 

(see 

Unpacking & Installation instruction #5).

If the machine is found to be damaged, save the packaging material and contact the carrier within fifteen (15) days of delivery. 

Immediately contact 

Supera 

or your local dealer of the equipment. 

You have no recourse to damage after fifteen (15) days.

TO AVOID SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE:

 

 

© Supera, 2013  

 

Version 1 | June 2013 | Hot Plates/Cooktops

 

Page 4

www.SuperaCo.com

Summary of Contents for LC2BCT-1

Page 1: ...neCook Pro Gas Hot Plates Cooktops Models LC2BCT 1 LC4BCT 1 LC6BCT 1 Supera Customer Care Toll Free Service Line 1 866 953 3288 For additional product and warranty information please visit our website...

Page 2: ...LATION 4 5 WARNINGS SAFEGUARDS FOR OPERATION 6 OPERATING INSTRUCTIONS 7 CLEANING INSTRUCTIONS 8 TROUBLESHOOTING 9 Table of Contents Supera 2013 Version 1 June 2013 Hot Plates Cooktops Page 2 www Super...

Page 3: ...d conversions are to be made solely by an authorized Supera servicer Owners should also ensure that no customers visitors or other unauthorized personnel come in contact with this equip ment Please re...

Page 4: ...e disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa These models are designed built and sold for commercial use only...

Page 5: ...set at 4 Natural Gas W C 7 THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Non combustible clearances 6 sides 152 mm 6 rear 152 mm 4 floor 102 mm 8 Do not obstruct the flow...

Page 6: ...night Do not operate any equipment with a damaged or leaking gas line ignitor or valves or if the unit is dropped or damaged in any manner Call for service The use of attachments not recommended or so...

Page 7: ...n the valve to adjust the flame height to your desired level Shutdown Turn the unit off by rotating the gas control knob clockwise to the OFF position The pilot light will remain lit To extinguish the...

Page 8: ...HE HOT PLATE COOKTOP S PILOT LIGHTS RECOMMENDED CLEANING It takes very little time and effort to keep the hot plate cooktop attractive and performing at top efficiency Wait until the griddle is cool a...

Page 9: ...on anything electrical call for service Cooking surface is heating up slowly Carbon build up Gas type of unit needs to be converted Unit ships from the factory Natural Gas Conversion from Natural Gas...

Reviews: