background image

 

 

  

 

 

 

 

 

 

        

INSTALLATION

1. Read this manual thoroughly before installation and operation. 

DO NOT

 proceed with installation and opera-

tion if you have any questions or do not understand anything in this manual. Contact your local representative or 

Supera 

first.

2. Select a location for the 

hot plate/cooktop 

that has a level, solid, non-skid surface that is nonflammable and 

away from water hazards or sinks, and is in a well-lighted work area away from children and visitors.

3. Equipment must be installed under proper ventilation as required per local code.

NOTICE: 

Local codes regarding installation and ventilation vary greatly by area. The National Fire Protection 

Association, Inc, states that local codes are “authority having jurisdiction” when it comes to requirements for 

installation of equipment. Therefore, installation should comply with all local codes.

4. Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Legs must 

be installed to adequately provide proper ventilation to the unit. 

5. Level unit by adjusting the four feet and tighten securely. The adjustable feet have an adjustment of 1” for 

lineup with other 

Supera - LineCook Pro 

countertop lines. Do not slide unit with legs mounted; lift if necessary 

to move unit. 

6. The supplied gas pressure regulator is factory set at 4'' Natural Gas W.C. 

7. 

THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.

 Non-

combustible clearances: 6'' sides (152 mm) 6'' rear (152 mm) 4'' floor (102 mm)

8. Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the 

flue. Do not place objects between the bottom of the unit and the counter top.

9. There must be adequate clearance for removal of the front panel. All major parts except the burners are 

removable through the front if the gas line is disconnected.

10. It may be necessary to adjust the balance of gas volume and air supply to each burner. This must be done 

by an authorized service technician.

11. Pipe threading compound must be resistant to the action of liquefied petroleum gases

Unpacking & Installation:

DO NOT use an open flame to check for leaks. Check all gas piping for leaks 

with a soap and water solution before operating unit.

COMMISSIONING

Commissioning of your new 

hot plate/cooktop 

is of the utmost importance. Commissioning is the thorough and 

methodical testing of the equipment, sub systems, and systems to ensure that the final product functions prop-

erly and safely at the work site. By identifying any potential problems (i.e.: equipment location, ventilation, local 

fire/electrical codes, installation, operator training and certification) prior to equipment being placed into service, 

costly outages and potential damages may be avoided.

 

 

© Supera, 2013  

 

Version 1 | June 2013 | Hot Plates/Cooktops 

Page 5

www.SuperaCo.com

Summary of Contents for LC2BCT-1

Page 1: ...neCook Pro Gas Hot Plates Cooktops Models LC2BCT 1 LC4BCT 1 LC6BCT 1 Supera Customer Care Toll Free Service Line 1 866 953 3288 For additional product and warranty information please visit our website...

Page 2: ...LATION 4 5 WARNINGS SAFEGUARDS FOR OPERATION 6 OPERATING INSTRUCTIONS 7 CLEANING INSTRUCTIONS 8 TROUBLESHOOTING 9 Table of Contents Supera 2013 Version 1 June 2013 Hot Plates Cooktops Page 2 www Super...

Page 3: ...d conversions are to be made solely by an authorized Supera servicer Owners should also ensure that no customers visitors or other unauthorized personnel come in contact with this equip ment Please re...

Page 4: ...e disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa These models are designed built and sold for commercial use only...

Page 5: ...set at 4 Natural Gas W C 7 THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Non combustible clearances 6 sides 152 mm 6 rear 152 mm 4 floor 102 mm 8 Do not obstruct the flow...

Page 6: ...night Do not operate any equipment with a damaged or leaking gas line ignitor or valves or if the unit is dropped or damaged in any manner Call for service The use of attachments not recommended or so...

Page 7: ...n the valve to adjust the flame height to your desired level Shutdown Turn the unit off by rotating the gas control knob clockwise to the OFF position The pilot light will remain lit To extinguish the...

Page 8: ...HE HOT PLATE COOKTOP S PILOT LIGHTS RECOMMENDED CLEANING It takes very little time and effort to keep the hot plate cooktop attractive and performing at top efficiency Wait until the griddle is cool a...

Page 9: ...on anything electrical call for service Cooking surface is heating up slowly Carbon build up Gas type of unit needs to be converted Unit ships from the factory Natural Gas Conversion from Natural Gas...