6.

9. Make certain that the end of the tubing to be connected to the equipment is clean and sanitized.

10. Connect tubing to equipment. Open all water supply valves and check for leaks.

11. If no leaks, turn on equipment and check for normal operation.

12. Attach the Service Log to the Installed Supera® Water Filtration System and fill in install date.

Operation

With adequate pressure, normal operation of the Supera® Water Filtration System is completely automatic. Depend-
able operation involves only monitoring of outlet pressure, periodic filter changes and service documentation.

Pressure Gauge Monitoring

Periodically monitor the pressure gauge on the Supera® Water Filtration System unit. If the needle on the gauge ever 
enters the red zone it may be an indication that the filters have become clogged with sediment. Ideally the pressure 
should never drop into the red zone.

 

 

© Supera, 2013 

v1 IFIFPSERIES 

Page 3

Filter Cartridge Replacement Procedure

IMPORTANT: Determine whether all equipment connected to the Supera® Water 
Filtration System
 must be turned off prior to shutting off water supply from 
filters.

1. If required, turn off equipment.

2. Turn OFF water to Supera® Water Filtration System by closing Inlet Ball 
Valve.

3. Press the red button to release pressure.

4. Remove housing(s) - use filter wrench if necessary.

5. Clean inside of housing sumps with warm water. If desired, disinfect housings 
using a teaspoon of household bleach in a filter bowl of water. Let stand 5 
minutes, and then discard and thoroughly rinse sump.

6. Insert new cartridges into filter housings. Match cartridge model numbers to 
model numbers on the system bracket.

7.  Make certain the O-ring is properly positioned and reinstall filter housings 

(hand tighten only - the filter wrench is not required).

 Check O-ring for damage 

and replace if damaged or distorted.

8. Slightly open the inlet ball valve; push the red pressure relief button to release 
trapped air until a small amount of water comes out - release the red button and 
fully open the ball valve.

9. Open the flush valve downline from the filter housing (if equipped) and flush 
the new cartridges to drain or bucket for two (2) minutes or until water runs clear. 
If no flush valve is present, disconnect line from equipment to flush to drain.

10.VERY IMPORTANT: With water supply inlet valve OPEN and water flow 
confirmed, turn on connected equipment. Failure to supply water to equipment 
may cause serious damage.

11. Record filter change.

Replacement Filter Cartridges 

Supera® Water Filtration Systems are designed, tested, and certified with 
Supera® filter cartridges with proven performance, size and operating 
capacities. Use of replacement cartridges other than those specified will void 
warranties, certifications and may compromise equipment protection, water 
quality and cartridge life.

2.

3.

4.

6.

7.

8.

Reviews: