Installation Precautions

•  Do NOT install the system backwards with the feed water line connected to the outlet.
•  Do NOT use liquid pipe compounds for fitting connections. USE two to three wraps of teflon tape.
•  Do NOT allow system to freeze. Turn off water supply to housing and drain housing if temperature falls below 32°F.
•  Do NOT install system in direct sunlight or where system is exposed to harsh chemicals or may be subjected to being 
  struck by moving equipment, carts, mops or any other item that may cause damage.
•  IF water hammer is evident, install water hammer arrestors before 

Supera® 

unit.

Installation Procedure

1.

 Turn off all equipment to be fed by the 

Supera® Water Filtration System

.

2.

 Locate water supply cut-off valve and turn off.

3.

 Install a 1/2” full-flow ball valve on the water supply side that will feed the water system.

4.

 Anchor the 

Supera® Water Filtration System

 on a wall stud or suitable mounting material spanning wall studs.

5.

 Run a suitable line from the 1/2” full-flow ball valve at the tap water source to the inlet ball valve on the left side of the 

Supera® Water Filtration System

. Use 2-3 wraps of teflon tape and brace the inlet ball valve on the system with a wrench 

when connecting the feed water line. 

NOTE: DO NOT OVERTIGHTEN CONNECTION FITTING INTO BALL VALVE.

6.

 Select the appropriate size tubing for the equipment being fed and connect it to the outlet of the 

Supera® Water Filtration 

System

NOTE: 

DO NOT connect the tubing to the equipment at this time. Prior to making connection to the equipment this 

line will be used to facilitate fl ushing the system. As an option, a drain valve in a tee on the outlet side of the 

Supera®

 

Water 

Filtration System 

could be provided in the line to facilitate fl ushing when changing filters.

7.

 With 

Supera® 

inlet valve closed, slowly open the 1/2” full-flow ball valve at the tap water source. Check for leaks.

8.

 If a drain valve was not installed on the outlet side of the system, hold the tubing that will connect to equipment in a clean 

bucket or over sink or drain. Open the system inlet feed valve and allow water to flush through system for 10 minutes at the 
specified  system  flow  rate  to  allow  air  and  any  carbon  fines  to  escape. 

NOTE: NO ACTIVATION IS REQUIRED FOR THE 

SUPERA® WATER FILTRATION SYSTEM TO PERFORM PROPERLY. FLUSHING IS RECOMMENDED TO ALLOW AIR TO 
ESCAPE THE SYSTEM AND REMOVE ANY CARBON FINES PRIOR TO CONNECTING TO EQUIPMENT.

Model IFP-C15F20

Capacity: 

30,000 gals./113,600 L

Service Flow Rate: 

3 gpm/11.3 lpm

Model IF-C24F40

Capacity: 

60,000 gals./227,100 L

Service Flow Rate: 

6 gpm/22.7 lpm

Model IFP-C24F40

Capacity: 

60,000 gals./227,100 L

Service Flow Rate: 

6 gpm/22.7 lpm

Reviews: