background image

Installation and Service Guide

Reverse Osmosis System with Quick-Connect Fittings

 

Please read this manual carefully

before attempting installation

Summary of Contents for USRO4-60-QC

Page 1: ...Installation and Service Guide Reverse Osmosis System with Quick Connect Fittings Please read this manual carefully before attempting installation ...

Page 2: ...he pipe firmly in position while the O Ring provides a permanent leak proof seal Pull on the pipe to check it is secure It is good practice to test the system prior to leaving site and or before use Disconnecting standard Quick connect fittings Ensure system is depressurized before removing fittings Push in the collet against the face of the fitting With the collet held in this position the pipe c...

Page 3: ...t pull back gently on the tubing it should catch Always check for leaks to ensure a watertight connection see Figure 1 Tools The following tools may be necessary depending on each particular installation variable speed electric drill 2 500 RPM is best for stainless steel metal cutting bits Concrete drill bits for porcelain sinks Phillips head screw driver 6 adjustable wrench Teflon tape Plastic tu...

Page 4: ...hipping or scratching Procedures 1 Mark the center with center punch for the 1 4 pilot hole 2 Carefully drill pilot hole with masonry pit through porcelain and stop when metal shows Use light pressure and slow speed 3 Switch the bit to a standard metal cutting bit to continue to cut through the metal below the porcelain surface 4 Continue to enlarge the pilot hole with larger masonry metal cutting...

Page 5: ...nect tubing to feed water valve using brass compression nut stiffener insert and plastic sleeve 8 Turn on cold water supply 9 To open valve turn handle counterclockwise 4 Drain Saddle Valve Installation See Figure 3 A Drain Saddle is used to make a wastewater connection with the drain under the sink which is designed to fit around a standard 1 1 2 OD drainpipe The drain saddle valve should always ...

Page 6: ... connect a T with a shut off valve into the faucet tubing and route tubing to the refrigerator Hooking up to existing copper tubing is not recommended due to possible corrosion Turn off icemaker inside freezer prior to turning off the existing tap water supply line to the refrigerator Turn on the icemaker after the RO system has been drained several times and the tank has a full supply of water Ic...

Page 7: ...run for 5 minutes 10 Shut off feed pressure 11 Allow solution to stand for 30 minutes 12 Open faucet and allow system to drain 13 Remove water from housings before installing new filters and membrane 14 Install new filters tighten housings and reconnect all tubing connections 15 Open feed pressure valve and check for leaks 16 Allow the system to make a full tank of water 17 Run 2 cycles to drain t...

Page 8: ...15 69 0 4619 0 5279 0 5938 0 6598 0 7258 0 7918 0 8578 0 9238 0 9897 1 0557 1 1217 1 1877 1 2537 1 3197 1 3856 1 4516 70 0 4715 0 5388 0 6062 0 6735 0 7409 0 8082 0 8756 0 9429 1 0103 1 0776 1 1450 1 2123 1 2797 1 3470 1 4144 1 4817 71 0 4810 0 5497 0 6185 0 6872 0 7559 0 8246 0 8933 0 9621 1 0308 1 0995 1 1682 1 2369 1 3056 1 3744 1 4431 1 5118 72 0 4906 0 5607 0 6308 0 7009 0 7709 0 8410 0 9111 ...

Page 9: ......

Reviews: