5
•
GKD
Features
(1) Activated Carbon Can Be Added Into the First Chamber to
Filter Out The Particles Contain in the solution, Second
Chamber Will Filter Out All The Organic Matter.
(2) Second Chamber's Filter Can Be Replace While First
Chamber Is Still Operating.
(3) Various Filtration Methods Are Available For Chamber One
.
(Paper, Cartridge Plate Fixture, Strainer Plate Fixture &Star Cloth Bag)
•
GKD
Operation
(1) Please Read Page 10~12 For Guidence
(2) Valve(F)(G)Should Be Fully Open While Operating.Rest
Should Be Fully Closed.
(Check Valve Function & Specification on Pg.4)
(3) Valve(E)Should Be Fully Open,When First Chamber Is
The Only Operating Chamber. Rest Should Be Closed.
(Check Valve Function & Specification on Pg.4)
•
GKD
Filter Replacement
(1) Before Replacing The Filter,Air Release Valve (I) Should
Be Open and Solution Should Be Fully Drained.
(2) Please Read Page 15 before Removing the Cartridge.
(3) First Remove Top Cover,Then Remove C Clamp,Pull The
Cartridge Vertically.The Stanchion Nut can Be Remove By
Turning Counter-Clockwise. Filter Media Can Be Access After
Above Procedure.
(4) After Replacing The Filter Reverse The Procedure On
Step 3 Before Operating.