Super Systems A20831-CH4 Operation Manual Download Page 30

Single Gas Sensor Module (SGSM) 

Operations Manual 

  

Super Systems Inc.    

Page 30 of 30 

Page 30 of 51  

 

 
 
 
Revision History 
 

Rev. 

Description 

Date 

MCO # 

New 

Initial release 

1/6/2017 

2204 

Added Configuration Board Diagram and DIP 

Switch Example Appendix 

6/1/2017 

2218 

Added Calibration instructions and 

information on new web pages, updated 

Modbus chart, various other minor 

corrections 

1/19/2022 

2317 

 

 

 

 

 
 

Summary of Contents for A20831-CH4

Page 1: ...Single Gas Sensor Module CO CO2 or CH4 measurement OPERATIONS MANUAL Super Systems Inc 7205 Edington Drive Cincinnati OH 45249 513 772 0060 Fax 513 772 9466 www supersystems com...

Page 2: ...1 306 5180 http www supersystemseurope com Super Systems M xico Sistemas Superiores Integrales S de RL de CV Acceso IV No 31 Int H Parque Industrial Benito Juarez C P 76120 Quer taro Qro Phone 52 442...

Page 3: ...ng 6 Modbus 6 Modbus Registers 7 Initial Network Configuration 15 nLocateIP Method 15 Control Interface via Web Browser 17 Main 18 Instrument Information 18 Sensor Information 19 Instrument Configurat...

Page 4: ...t Specifications CO2 Sensor Standard Range 0 2 000 Optional High Range 0 20 00 Accuracy Standard Range 1 of full scale 0 02 of gas concentration Accuracy High Range 1 of full scale 0 2 of gas concentr...

Page 5: ...tion HMI This is the connection for an HMI RS485 1 This is a communications port used for when this device is the Client RS485 2 This is a communications port used for when this device is the Host to...

Page 6: ...eel compression fittings have been plumbed The compression fittings are sized to handle OD tubing This unit is designed to be mounted to 35mm DIN rail Figure 2 Connection diagram for gas inlet outlet...

Page 7: ...e 1 Sensor Driver VERSION_NUMBER 0 Current version number of the firmware UART_1_MODE 1 0 slave 1 Sensor Driver UART_1_BAUD_RATE 2 Baud Rate 0 1200 5 19200 10 115200 UART_2_MODE 3 0 slave 1 Sensor Dri...

Page 8: ...6 NDIR gas CUR_LOOP_ZERO 28 Zero value This value equates to either 4 mA or 0 mA CUR_LOOP_SPAN 30 Span value This value equates to either 20 mA CUR_LOOP_MANUAL 32 If manual mode is set then this regi...

Page 9: ...h MB_SET_TM_MDAY 509 set day of month MB_SET_TM_WDAY 510 set day of week 0 Sunday MB_SET_TM_HOUR 511 set hour MB_SET_TM_MIN 512 set minute MB_SET_TM_SEC 513 set second MB_TM_YEAR 514 year MB_TM_MON 51...

Page 10: ...AX 933 Max Round robin time ms DIGIO_RR_TIME 934 Round robin time ms DIGIO_RR_TIME_MAX 935 Max Round robin time ms UART_1_PARITY 940 0 8N1 1 8E1 2 8N2 UART_2_PARITY 941 0 8N1 1 8E1 2 8N2 UART_3_PARITY...

Page 11: ...negative number zero SENSOR_GEN_QUEUE_ENABLE 1150 Allows for a generic write SENSOR_GEN_QUEUE_START 1151 Start of write E g register 45 SENSOR_GEN_QUEUE_ADDRESS 1152 Address of board to write to SENSO...

Page 12: ...to display temperature MB_READ_N2_FLOW 1218 N2 flow MB_READ_NH3_FLOW 1219 NH3 flow MB_READ_DA_FLOW 1220 DA flow MB_READ_H2_FLOW 1221 H2 Flow MB_READ_PV_MODE 1222 Process variable 0 H2 1 DA 2 NH3 3 Kn...

Page 13: ...Gas pressure absolute MB_READ_NDIR_GAS_SELECTION 1253 0 7 TBD MB_READ_NDIR_GAS_VPP 1254 Peak peak voltages MB_READ_NDIR_GAS_VPP_SF 1258 Peak peak voltages No high low values MB_READ_NDIR_GAS_VPP_FIR 1...

Page 14: ...ms MB_READ_MAX_ROUND_ROBIN_US 1308 Max Round robin time us MB_READ_EEPROM_WRITER_COUNT 1309 Counts the number of times EEPROM has been written not saved MB_READ_SPAN_MULTIPLIER 1310 Shows the span mu...

Page 15: ...MB_DIGIO_EVENT_OUT_SP_CP 1638 Copy of Output setpoint SENSOR_SUB_SERIAL_NUM 1700 serial number of sensor board Initial Network Configuration This section is intended for use by persons familiar with...

Page 16: ...ifying text in the list of instruments It includes the type of instrument and serial number It also provides the IP Address information for the sensor 5 Click the Configure button and choose the senso...

Page 17: ...mends consulting an IT engineer or network administrator If needed call SSi at 513 772 0060 Control Interface via Web Browser The SGSM can be controlled using a web browser on your computer The web br...

Page 18: ...percentage composition of the gas is displayed Figure 3 Main Page with CO CO2 CH4 Percentage Shown Instrument Information The Instrument Information page provides a description of the SGSM the part nu...

Page 19: ...s pressure measured inside of the NDIR chamber Zero Ref Vdc Voltage PV of the NDIR reference channel during a zero calibration Zero Gas Vdc Voltage PV of the NDIR sensing channel during a zero calibra...

Page 20: ...on Page Output Configuration The Output Configuration options allows the user to set up an analog output milliamp signal from the SGSM to a chart recorder or other device for recording or controlling...

Page 21: ...pplicable Set button to set each parameter for example use Set Source to set the source Figure 7 Output Configuration Page Output Calibration The SGSM is equipped with two analog outputs These outputs...

Page 22: ...on To ensure accurate readings the gas sensor must be calibrated at the low end and high end of the measured gas composition range Never perform a span calibration without first performing a zero cali...

Page 23: ...tion Timer has counted down the zero value will be calibrated NOTE The remaining steps for the span gas will be very similar to the steps performed for the zero gas calibration 7 Ensure that the syste...

Page 24: ...hen any alarm condition is met Contact SSi for additional information on the alarm feature for this product Figure 10 Alarms Page SSI Configuration IMPORTANT It is highly recommended that changes on t...

Page 25: ...he specified register location The Set Val button when pressed will commit the entered value to the specified register location Figure 11 SSI Configuration Page Read Write Registers The Read Write Reg...

Page 26: ...ge allows you to view network settings and change certain settings as well SSi recommends consulting an IT engineer or network administrator before changing any of these settings Figure 13 Network Boa...

Page 27: ...cts The network must support dynamic IP assignment in order for this to work If Enable DHCP is not checked IP and other settings can be changed manually These settings should be verified with your net...

Page 28: ...D WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SOME JURISDICTIONS DO NOT ALLOW THE LIMITATION OF IMPLIED WARRANTIES SO THIS LIMITATION MAY NOT APPLY TO YOU SSI is n...

Page 29: ...n n n n Address 4 Address 12 Address 20 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON n ON n n ON n n OFF n n n n n n n OFF n n n n n n OFF n n n n n n Address 5 Address 13 Address 21 1 2 3 4 5...

Page 30: ...on History Rev Description Date MCO New Initial release 1 6 2017 2204 A Added Configuration Board Diagram and DIP Switch Example Appendix 6 1 2017 2218 B Added Calibration instructions and information...

Reviews: