NOTE:

 The maintain mode technology utilized in this charger allows you 

to safely charge and maintain a healthy battery for extended periods of 

time. However, problems with the battery, electrical problems in the vehicle, 

improper connections or other unanticipated conditions could cause excessive 

current draws. As such, occasionally monitoring your battery and the charging 

process is recommended.

DESULFATION MODE

If the battery is left discharged for an extended period of time, it could become 

sulfated and not accept a normal charge. If the charger detects a sulfated 

battery, the charger will switch to a special mode of operation designed for 

such batteries. If successful, normal charging will resume after the battery is 

desulfated. Desulfation could take up to 8 hours. If desulfation fails, charging 

will abort, the yellow LED will blink, and the display will show “CHARGING 

ABORTED BAD BATTERY”.

ABORTED CHARGE

If charging cannot be completed normally, charging will abort. When charging 

aborts, the charger’s output is shut off, the yellow LED will blink, and the display 

will show “CHARGING ABORTED BAD BATTERY”. To reset after an aborted 

charge, unplug the charger from the outlet, wait a few moments and plug it back in.

DISPLAY MESSAGES

CONNECT CLAMPS

 (No LED lit) – Plugged into the AC outlet without the 

clamps connected to a battery.

WARNING CLAMPS REVERSED

 (no LED lit) – Plugged into the AC outlet and the 

clamps are connected backwards to a 6V or 12V battery.

ANALYZING BATTERY

 (No LED lit) – Plugged into the AC outlet, and when 

first connected to a 6V or 12V battery correctly.

CHARGING 12V – XX%

 (Yellow LED lit) – Plugged into the AC outlet and 

correctly connected to a discharged 12V battery.

CHARGING 6V – XX%

 (Yellow LED lit) – Plugged into the AC outlet and 

correctly connected to a discharged 6V battery.

FULLY CHARGED AUTO MAINTAINING

 (Green LED lit) – Plugged into the 

AC outlet and correctly connected to a fully charged 6V or 12V battery.

CHARGING ABORTED BAD BATTERY 

(Yellow LED blinking)

 

MAINTENANCE AND CARE

A minimal amount of care can keep you battery charger working properly for years.

• 

Clean the clamps each time you are finished charging. Wipe off any battery 

fluid that may have come in contact with the clamps, to prevent corrosion.

• 

Occasionally cleaning the case of the charger with a soft cloth will keep the finish 

shiny and help prevent corrosion.

Summary of Contents for SPSS3

Page 1: ...utomatic Battery Charger PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE This manual will explain how to use the battery charger safely and effectively Please read and follow these instruction...

Page 2: ...r other reproductive harm Wash hands after handling Keep out of reach of children Use the battery charger on 6 and 12V LEAD ACID and AGM type rechargeable batteries as used in automobiles trucks tract...

Page 3: ...ARNING RISK OF EXPLOSIVE GAS Operate the charger as far away from the battery as DC charger cables permit Do not expose the charger to rain or snow NEVER charge a frozen battery NEVER overcharge a bat...

Page 4: ...nded to reduce the risk of electric shock The electrical outlet must be properly installed and grounded in accordance with all local codes and ordinances The plug pins must fit the receptacle outlet D...

Page 5: ...in maintain mode OPERATING INSTRUCTIONS IMPORTANT Do not start the vehicle with the charger connected to the AC outlet or it could result in damage to the charger CHARGING A BATTERY IN THE VEHICLE 1...

Page 6: ...ctrical outlet 7 When charging is complete disconnect the charger from the AC power disconnect the negative clamp and finally the positive clamp 8 A marine boat battery must be removed and charged on...

Page 7: ...good connection If the display shows WARNING CLAMPS REVERSED unplug the charger from the AC outlet and reverse the connections at the battery CHARGE COMPLETION AND MAINTAIN MODE FLOAT MODE MONITORING...

Page 8: ...will show CHARGING ABORTED BAD BATTERY To reset after an aborted charge unplug the charger from the outlet wait a few moments and plug it back in DISPLAY MESSAGES CONNECT CLAMPS No LED lit Plugged int...

Page 9: ...connection at battery and frame Replace the in line fuse for the ring connector The display shows ANALYZING BATTERY and yellow LED is lit The charger is checking the condition of the battery No probl...

Page 10: ...duct is misused subjected to careless handling repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties...

Page 11: ...Electric Corporation 801 Business Center Drive Mount Prospect IL 60056 2179 Name_______________________________________________________________ Street Address_________________________________________...