7. 

For a positive-ground vehicle, connect the charger’s NEGATIVE (BLACK) 

clamp to the NEGATIVE (NEG, N, -) battery post. Next, connect the 

charger’s POSITIVE (RED) clamp to the vehicle chassis or engine block 

away from the battery. NEVER connect any clamps to the carburetor, fuel 

lines or sheet-metal body parts.

8. 

Connect the charger to an electrical outlet.

9. 

When charging is complete, disconnect the charger from the AC power, 

remove the clamps from the vehicle’s chassis, and then remove the clamp 

from the battery terminal.

CHARGING A BATTERY OUTSIDE OF THE VEHICLE

1. 

Place battery in a well-ventilated area.

2. 

Clean the battery terminals.

3. 

Connect a 24-inch long, 6-gauge (AWG) insulated battery cable to the 

NEGATIVE (NEG, N, -) battery post (i.e., jumper cable) (not provided).

4. 

Connect the POSITIVE (RED) clamp to the POSITIVE (POS, P, +) 

battery post. 

5. 

Position yourself and the “negative post extension” cable as far away 

from the battery as possible, and connect the NEGATIVE (BLACK) clamp 

to the cable’s free end.

6. 

Connect the charger to the electrical outlet.

7. 

When charging is complete, disconnect the charger from the AC power, 

disconnect the negative clamp, and finally the positive clamp.

8. 

A marine (boat) battery must be removed and charged on shore.

NOTE:

 This charger is equipped with an auto-start feature. Current will not 

be supplied to the battery clamps until a battery is properly connected. The 

clamps will not spark if touched together. 

USING THE QUICK-CONNECT CABLE CONNECTORS

Connect any of the three output cable leads to the charger. Make sure to place 

the charger on a dry, non-flammable surface.

NOTE:

 Never connect the clamp and ring terminal connectors together for use 

in other applications, such as external battery or other power source charging, 

or to extend the output cable length, as reverse polarity and/or overcharge 

conditions will occur.

USING THE 50 AMP BATTERY CLAMPS 

1. 

Connect the end of the charger output cable to the end of the battery 

cable, quick-disconnect and clamps. 

2. 

Follow the steps in sections CHARGING A BATTERY IN THE VEHICLE 

or CHARGING A BATTERY OUTSIDE OF THE VEHICLE to connect the 

output clamps to the battery. 

3. 

After a good electrical connection is made to the battery, connect the 

battery to an electrical power outlet. 

Summary of Contents for SPSS3

Page 1: ...utomatic Battery Charger PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE This manual will explain how to use the battery charger safely and effectively Please read and follow these instruction...

Page 2: ...r other reproductive harm Wash hands after handling Keep out of reach of children Use the battery charger on 6 and 12V LEAD ACID and AGM type rechargeable batteries as used in automobiles trucks tract...

Page 3: ...ARNING RISK OF EXPLOSIVE GAS Operate the charger as far away from the battery as DC charger cables permit Do not expose the charger to rain or snow NEVER charge a frozen battery NEVER overcharge a bat...

Page 4: ...nded to reduce the risk of electric shock The electrical outlet must be properly installed and grounded in accordance with all local codes and ordinances The plug pins must fit the receptacle outlet D...

Page 5: ...in maintain mode OPERATING INSTRUCTIONS IMPORTANT Do not start the vehicle with the charger connected to the AC outlet or it could result in damage to the charger CHARGING A BATTERY IN THE VEHICLE 1...

Page 6: ...ctrical outlet 7 When charging is complete disconnect the charger from the AC power disconnect the negative clamp and finally the positive clamp 8 A marine boat battery must be removed and charged on...

Page 7: ...good connection If the display shows WARNING CLAMPS REVERSED unplug the charger from the AC outlet and reverse the connections at the battery CHARGE COMPLETION AND MAINTAIN MODE FLOAT MODE MONITORING...

Page 8: ...will show CHARGING ABORTED BAD BATTERY To reset after an aborted charge unplug the charger from the outlet wait a few moments and plug it back in DISPLAY MESSAGES CONNECT CLAMPS No LED lit Plugged int...