Super Start SPSS3 Owner'S Manual Download Page 7

• 7 •

USING THE QUICK-CONNECT CABLE 

1. 

To permanently attach to a battery, loosen and remove each nut from the 

bolt at the battery terminal. 

2. 

Connect the red POSITIVE connector ring to the POSITIVE battery terminal. 

3. 

Connect the black NEGATIVE connector ring to the NEGATIVE battery 

terminal. 

4. 

Replace and tighten the nuts to secure. 

5. 

Connect the cable to the end of the charger output cord.  

(Keep the wires and plug away from metal and moving parts.) 

6. 

Connect the charger to an electrical power outlet. 

USING THE CORD SET WITH 12V ADAPTER

1. 

Connect the end of the cord set with 12V cigarette adapter to the charger.

2. 

Insert the 12V accessory plug into the 12V accessory outlet.

3. 

Route the power cord from the charger through the vehicle’s open window.

4. 

Connect the charger to an electrical power outlet. 

BATTERY CONNECTION INDICATOR

If the charger does not detect a properly connected battery, charging will not 

start and the digital display will show one of two messages. If the display 

shows “CONNECT CLAMPS”, make sure the charger is connected to the 

battery and the connection points are clean and making a good connection. 

If the display shows “WARNING CLAMPS REVERSED”, unplug the charger 

from the AC outlet and reverse the connections at the battery.

CHARGE COMPLETION AND MAINTAIN MODE (FLOAT-MODE MONITORING)

Charge completion is indicated by the CHARGED (green) LED turning on and 

the digital display showing “FULLY CHARGED AUTO MAINTAINING”. This 

means that the charger has stopped charging and has switched to the maintain 

mode of operation. 

NOTE:

 If the charger has to provide its maximum maintain 

current for a continuous 12 hour period, it will go into abort mode (see Aborted 

Charge section). This is usually caused by a drain on the battery, or the battery 

could be bad. Make sure there are no loads on the battery. If there are, remove 

them. If there are none, have the battery checked or replaced.

MAINTAINING A BATTERY

The SPSS3 maintains both 6 and 12 volt batteries, keeping them at full charge. 

It can charge small batteries and maintain both small and large batteries. If you 

are maintaining a fully charged large battery, you are properly utilizing the battery 

charger. However, if you use this battery charger to charge a large battery, such 

as a marine deep-cycle battery, that was not fully charged, you may lose some 

of the battery’s capacity. 

Therefore, we do not recommend charging a large 

battery with this unit.

Summary of Contents for SPSS3

Page 1: ...utomatic Battery Charger PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE This manual will explain how to use the battery charger safely and effectively Please read and follow these instruction...

Page 2: ...r other reproductive harm Wash hands after handling Keep out of reach of children Use the battery charger on 6 and 12V LEAD ACID and AGM type rechargeable batteries as used in automobiles trucks tract...

Page 3: ...ARNING RISK OF EXPLOSIVE GAS Operate the charger as far away from the battery as DC charger cables permit Do not expose the charger to rain or snow NEVER charge a frozen battery NEVER overcharge a bat...

Page 4: ...nded to reduce the risk of electric shock The electrical outlet must be properly installed and grounded in accordance with all local codes and ordinances The plug pins must fit the receptacle outlet D...

Page 5: ...in maintain mode OPERATING INSTRUCTIONS IMPORTANT Do not start the vehicle with the charger connected to the AC outlet or it could result in damage to the charger CHARGING A BATTERY IN THE VEHICLE 1...

Page 6: ...ctrical outlet 7 When charging is complete disconnect the charger from the AC power disconnect the negative clamp and finally the positive clamp 8 A marine boat battery must be removed and charged on...

Page 7: ...good connection If the display shows WARNING CLAMPS REVERSED unplug the charger from the AC outlet and reverse the connections at the battery CHARGE COMPLETION AND MAINTAIN MODE FLOAT MODE MONITORING...

Page 8: ...will show CHARGING ABORTED BAD BATTERY To reset after an aborted charge unplug the charger from the outlet wait a few moments and plug it back in DISPLAY MESSAGES CONNECT CLAMPS No LED lit Plugged int...