electrical lock

operator device

flashing light

bar antenna

main switch
emergency stop

control unit

photo sensor

photo sensor column

drive

G

G

E

E

N

N

E

E

R

R

A

A

L

L

 

 

A

A

S

S

S

S

E

E

M

M

B

B

L

L

Y

Y

 

 

S

S

P

P

E

E

C

C

I

I

F

F

I

I

C

C

A

A

T

T

I

I

O

O

N

N

S

S

C

C

a

a

b

b

l

l

e

e

-

-

 

 

a

a

n

n

d

d

 

 

 

 

m

m

i

i

n

n

i

i

m

m

u

u

m

m

 

 

c

c

r

r

o

o

s

s

s

s

-

-

s

s

e

e

c

c

t

t

i

i

o

o

n

n

If the control unit is arranged as a compactly component in the drive cage:
Feeder to control unit

5 x 1,5 mm²

H07RN-F

If the control unit is arranged external:
Ffeeder to control unit

5 x 1,5 mm²

H07RN-F

drive to control unit

5 x 1,5 mm²

H07RN-F

engine break at slide door drive

3 x 1,5 mm²

H07RN-F

mechanical end stop to control unit

2 x 2 x 0,8 mm²

A20-D

switch to control unit

2 x 2 x 0,8 mm²         A20-D

photo sensor transmitter to control unit

2 x 2 x 0,8 mm²         A20-D

photo sensor receiver to control unit

2 x 2 x 0,8 mm²         A20-D

key switch to control unit

2 x 2 x 0,8 mm²         A20-D

emergency stop to control unit

2 x 2 x 0,8 mm²         A20-D

flashing light ot control unit

3 x 1,5 mm²          H07RN-F

red/green-traffic light to control unit

3 x 1,5 mm²          H07RN-F

electrical lock to control unit

3 x 1,5 mm²          H07RN-F

strip at gate trailing- and leading edge,
current supply via trailing cable each

2 x 2 x 0,8 mm²         A20-D

strip guide pillar each

2 x 2 x 0,8 mm²         A20-D

induction loop detector to control unit

3 x 1,5 mm²          H07RN-F

+ 2 x 2 x 0,8 mm²   A20D

magnetic card reader

3 x 1,5 mm²          H07RN-F

+ 2 x 2 x 0,8 mm²   A20D

clock timer

3 x 1,5 mm²          H07RN-F

+ 2 x 2 x 0,8 mm²   A20D

-

  The feeder will be conducted over the main switch, which has to be completed with all poles disjunctive.

From main switch to the control unit.

-

  Radio-code keyboard cordless, will be controlled per radio, has an integrated power supply.

     Optional bar antenna for a broad reach.

Summary of Contents for 606S

Page 1: ...technical alterations 06 2006 www supeero de info supeero de 1 A As ss se em mb bl ly y i in ns st tr ru uc ct ti io on ns s a an nd d d di ir re ec ct ti io on ns s f fo or r u us se e e el le ek kt tr ro oh hy yd dr ra au ul li ic c o op pe er ra at to or r f fo or r h hi in ng ge ed d g ga at te es s ...

Page 2: ...t be controlled by the installed force coupler because of the special mounting form In principle every operator should know that power operated and remote controlled gates should be operated solely when there is intervisibility about the whole opening and closing stroke The enclosed condenser must be jammed parallel to the brown and black conductor T Te ec ch hn ni ic ca al l d da at ta a m mo ot ...

Page 3: ...f gate has a wide of 50 mm and fulcrum of gate band in gate centerline see drawing ATTENTION if the fulcrum of gate is displaced inwards the dimension will be E 110 mm referring to the centerline of fulcrum IMPORTANT If end switch are not used mechanical end stopps e g SUPEERO closure limiter for upper and nether floor drive are mandatory at the gate in open or closed positon ATTENTION non observa...

Page 4: ...er pay attention that the O ring won t get damaged The force at the foreside of gate should be adjusted in that way that pression of maximum 15kg exerts there After adjusting this please use only a clean screwdriver the emergency release cap will be attached and screwed on with 2 allen screws Using a motor control unit which has a separate electrical torque adjustment the maximum force in the cont...

Page 5: ...l l i in nd di ic ca ao or r gate leaf After the requirements of the new gate standard following minimum or maximum distances must be adhered to If one fall below this dimensions additional safety installations against crushing must be implemented At 1 and 2 winged hinged doors the wings need a mechanical end stop on closing and on opening Iif there are photo sensors between the haunch and behind ...

Page 6: ...D switch to control unit 2 x 2 x 0 8 mm A20 D photo sensor transmitter to control unit 2 x 2 x 0 8 mm A20 D photo sensor receiver to control unit 2 x 2 x 0 8 mm A20 D key switch to control unit 2 x 2 x 0 8 mm A20 D emergency stop to control unit 2 x 2 x 0 8 mm A20 D flashing light ot control unit 3 x 1 5 mm H07RN F red green traffic light to control unit 3 x 1 5 mm H07RN F electrical lock to contr...

Page 7: ... SUPEERO Systeme GmbH Im Bärengarten 2 72116 Mössingen Telefon 07473 94940 FAX 07473 25808 subject to technical alterations 06 2006 www supeero de info supeero de 7 packaging unit available devices ...

Page 8: ...peero de 8 U Up pp pe er r f fl lo oo or r h hi in ng ge ed d d do oo or r d dr ri iv ve e o ou ut tw wa ar rd ds s o op pe en ni in ng g I In nw wa ar rd d o op pe en ni in ng g i in ns su uf ff fi ic ce en nt t d di im me en ns si io on n s si id de ew wa ar rd ds s A B C Typ 302 160 mm 160 mm max 40 mm Typ 606 140 mm 140 mm max 80 mm dimensions in mm ...

Reviews: