background image

 

SUPEERO

 - Systeme GmbH - Im Bärengarten 2 - 72116 Mössingen

Telefon 07473/94940  FAX: 07473/25808

subject to technical alterations 06.2006

www.supeero.de - [email protected]

1

A

A

s

s

s

s

e

e

m

m

b

b

l

l

y

y

 

 

i

i

n

n

s

s

t

t

r

r

u

u

c

c

t

t

i

i

o

o

n

n

s

s

 

 

a

a

n

n

d

d

 

 

d

d

i

i

r

r

e

e

c

c

t

t

i

i

o

o

n

n

s

s

 

 

f

f

o

o

r

r

 

 

u

u

s

s

e

e

:

:

e

e

l

l

e

e

k

k

t

t

r

r

o

o

h

h

y

y

d

d

r

r

a

a

u

u

l

l

i

i

c

c

 

 

o

o

p

p

e

e

r

r

a

a

t

t

o

o

r

r

 

 

f

f

o

o

r

r

 

 

h

h

i

i

n

n

g

g

e

e

d

d

 

 

g

g

a

a

t

t

e

e

s

s

Summary of Contents for 606S

Page 1: ...technical alterations 06 2006 www supeero de info supeero de 1 A As ss se em mb bl ly y i in ns st tr ru uc ct ti io on ns s a an nd d d di ir re ec ct ti io on ns s f fo or r u us se e e el le ek kt tr ro oh hy yd dr ra au ul li ic c o op pe er ra at to or r f fo or r h hi in ng ge ed d g ga at te es s ...

Page 2: ...t be controlled by the installed force coupler because of the special mounting form In principle every operator should know that power operated and remote controlled gates should be operated solely when there is intervisibility about the whole opening and closing stroke The enclosed condenser must be jammed parallel to the brown and black conductor T Te ec ch hn ni ic ca al l d da at ta a m mo ot ...

Page 3: ...f gate has a wide of 50 mm and fulcrum of gate band in gate centerline see drawing ATTENTION if the fulcrum of gate is displaced inwards the dimension will be E 110 mm referring to the centerline of fulcrum IMPORTANT If end switch are not used mechanical end stopps e g SUPEERO closure limiter for upper and nether floor drive are mandatory at the gate in open or closed positon ATTENTION non observa...

Page 4: ...er pay attention that the O ring won t get damaged The force at the foreside of gate should be adjusted in that way that pression of maximum 15kg exerts there After adjusting this please use only a clean screwdriver the emergency release cap will be attached and screwed on with 2 allen screws Using a motor control unit which has a separate electrical torque adjustment the maximum force in the cont...

Page 5: ...l l i in nd di ic ca ao or r gate leaf After the requirements of the new gate standard following minimum or maximum distances must be adhered to If one fall below this dimensions additional safety installations against crushing must be implemented At 1 and 2 winged hinged doors the wings need a mechanical end stop on closing and on opening Iif there are photo sensors between the haunch and behind ...

Page 6: ...D switch to control unit 2 x 2 x 0 8 mm A20 D photo sensor transmitter to control unit 2 x 2 x 0 8 mm A20 D photo sensor receiver to control unit 2 x 2 x 0 8 mm A20 D key switch to control unit 2 x 2 x 0 8 mm A20 D emergency stop to control unit 2 x 2 x 0 8 mm A20 D flashing light ot control unit 3 x 1 5 mm H07RN F red green traffic light to control unit 3 x 1 5 mm H07RN F electrical lock to contr...

Page 7: ... SUPEERO Systeme GmbH Im Bärengarten 2 72116 Mössingen Telefon 07473 94940 FAX 07473 25808 subject to technical alterations 06 2006 www supeero de info supeero de 7 packaging unit available devices ...

Page 8: ...peero de 8 U Up pp pe er r f fl lo oo or r h hi in ng ge ed d d do oo or r d dr ri iv ve e o ou ut tw wa ar rd ds s o op pe en ni in ng g I In nw wa ar rd d o op pe en ni in ng g i in ns su uf ff fi ic ce en nt t d di im me en ns si io on n s si id de ew wa ar rd ds s A B C Typ 302 160 mm 160 mm max 40 mm Typ 606 140 mm 140 mm max 80 mm dimensions in mm ...

Reviews: