SUP'AIR manufactures its products in Europe. Most of the components used are
Made in Europe
.
S
UP’AIR
_
A
CRO
3
Page 15
User’s manual ACRO 3
B
Rescue parachute riser connection.
1
2
3
Installing the reserve parachutes.
1.
1. Place the Maillon Rapide®
( locking gate toward the top,
facing outward ) and push it
through the bridle loop under
the flap. Place the O ring in the
Maillon and twist it in a figure 8
configuration.
2.
2. Push the riser through the
upper free “8” shaped toric
ring and connect it to the Mail-
lon Rapide®.
3.
3. Create a new twisted
loop with the O ring before
inserting it into the Maillon
Rapide®.
4.
4. Repeat procedures 1,2,3
with an additional O ring for
the connection to the harness.
Tighten the Maillon Rapide®
locking gate securely, with pli-
ers if necessarily.
5.
5. Tuck away the
risers excess under the
flaps.
Regarding the second reserve para-
chute : complete the installation of the
first rescue in its pocket. Repeat the
procedure with a new set of Maillons Rapides®,
by overlapping the second riser set on the initial
arrangement. Install first the reserve parachute
to which the handle is found opposed to your
predilection side.