Safety Clearance / Certificate of Compliance with the Directives on the Connection and
Parallel Operation of In-Plant Generation Systems to the Low-Voltage Grid (VDEW
[German Electricity Association], 4th Edition 2001)
We hereby declare that the following product complies with the provisions of the appli-
cable VDE [German Association for Electrical, Electronic & Information Technologies]
directive for operation parallel to the grid. In particular, the directives for connection and
parallel operation of in-plant generation systems to the low-voltage grid of the energy
supply company (VDEW 4th edition 2001) and DIN 0838 are complied with.
Product
Manufacturer
Type
As from manufacturing date
Applied standards
Norm
Title
Edition
Solar Inverter
Sunways AG, Photovoltaic Technology
Macairestr. 3 - 5, D - 78467 Konstanz, Germany
Sunways NT 10000
15 September 2005
In-Plant Generation Systems to the
Low-Voltage Grid
4
th
edition 2001
Explanations
Sunways Solar Inverters of series NT 10000 are Solar Inverters that inject in three-phases and are not capable of isolated opera-
tion. The NT 10000 consists of three single-phase inverters with a three-phase voltage monitoring system that inject into different
phases. These integrated inverters control their phase angle independently of each other. They are equipped with a voltage-
monitoring system and a three-phase monitoring system for any reduction of the linked voltage, in accordance with section 2.4.2
of the VDEW directive (4th edition 2001). Therefore, no always accessible isolating point is required (see section 2.1.2 Schaltstelle
mit Trennfunktion [Control Point with Disconnection Function]). A routine test is carried out with each device to make sure the
turn-off values of the three-phase voltage reduction protection are maintained. Subject to changes. Currently valid edition availa-
ble at request.
For the latest valid version of this declaration, please visit our website www.sunways.de.
162
Place, date
Roland Burkhardt, Executive Board
Constance, 13 Sept. 2005
K36001_IH_NT_10000_e 13.12.2007 16:22 Uhr Seite 80
Summary of Contents for NT 10000
Page 2: ...500 mm 805 mm 175 mm...
Page 18: ...2 0 Hinweise zur Installation 18 K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 18...
Page 42: ...18 3 0 Hinweise zum Betrieb 42 K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 42...
Page 70: ...70 K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 70...
Page 71: ...18 4 0 Anhang 71 K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 71...
Page 85: ...K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 85...
Page 100: ...2 0 Installation Instructions 100 K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 18...
Page 124: ...18 3 0 Operating Instructions 124 K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 42...
Page 152: ...152 K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 70...
Page 153: ...18 4 0 Appendix 153 K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 71...
Page 167: ...K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 85...
Page 182: ...2 0 Indicaciones para la instalaci n 182 K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 18...
Page 206: ...18 3 0 Indicaciones de servicio 206 K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 42...
Page 234: ...234 K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 70...
Page 235: ...18 4 0 Anexo 235 K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 71...
Page 248: ...K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 84...
Page 249: ......