Errors 007 to 009
· Overheating
Your Solar Inverter is designed for an
ambient temperature of up to +40° C.
If the maximum temperature of the heat
sink is exceeded, the injection will stop.
When the heat sink temperature has
dropped, the Solar Inverter will automa-
tically restart. If the upper heat sink over-
heats, for example, «error 009» will be
flagged.
Errors 010 to 012
· Grid undervoltage 1-phase
Your Solar Inverter continuously monitors
the voltage level of the injection phase.
If it drops below the minimum admissible
limit value, the Solar Inverter will stop the
injection and only restart when the voltage
value rises above the minimum admissible
limit value. If the voltage of L1 drops
below 160 V, the Solar Inverter can no
longer be supplied, and the display will
switch off. If there is a grid undervoltage
on phase L3, for example, «error 012» will
be flagged.
Errors 013 to 015
· Grid overvoltage 1-phase
Your Solar Inverter continuously monitors
the voltage level of the injection phase.
If it rises above the maximum admissible
limit value, the Solar Inverter will stop the
injection and only restart when the voltage
value drops below the maximum admissi-
ble limit value. If there is a grid overvolta-
ge on phase L2, for example, «error 014»
will be flagged.
Error 016
· Grid undervoltage 3-phase
Your Solar Inverter is equipped with an
intrinsically safe 3-phase grid monitoring
system that complies with E DIN VDE
0126-1-1. The voltage level of phases L1,
L2, and L3 is continuously monitored.
If it drops below the minimum admissible
limit value, the Solar Inverter will stop the
injection and only restart when the voltage
value rises above the minimum admissible
limit value.
K36001_IH_NT_10000_e 13.12.2007 16:22 Uhr Seite 58
Summary of Contents for NT 10000
Page 2: ...500 mm 805 mm 175 mm...
Page 18: ...2 0 Hinweise zur Installation 18 K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 18...
Page 42: ...18 3 0 Hinweise zum Betrieb 42 K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 42...
Page 70: ...70 K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 70...
Page 71: ...18 4 0 Anhang 71 K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 71...
Page 85: ...K36001_IH_NT_10000_d 13 12 2007 16 16 Uhr Seite 85...
Page 100: ...2 0 Installation Instructions 100 K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 18...
Page 124: ...18 3 0 Operating Instructions 124 K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 42...
Page 152: ...152 K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 70...
Page 153: ...18 4 0 Appendix 153 K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 71...
Page 167: ...K36001_IH_NT_10000_e 13 12 2007 16 22 Uhr Seite 85...
Page 182: ...2 0 Indicaciones para la instalaci n 182 K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 18...
Page 206: ...18 3 0 Indicaciones de servicio 206 K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 42...
Page 234: ...234 K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 70...
Page 235: ...18 4 0 Anexo 235 K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 71...
Page 248: ...K36001_IH_NT_10000_s 13 12 2007 16 26 Uhr Seite 84...
Page 249: ......