5.12. Battery Discharge Page
To configure inverter’s shutdown settings, click on the BATTERY icon and then on ‘Shut Down’.
What this page displays:
Inverter shutdown voltage set as either a voltage or %.
Inverter low battery warning set as either a voltage or %.
Restart voltage set as either a voltage or %.
What you can do from this page:
Adjust battery shut down (voltage or %)
Adjust low battery warning (voltage or %)
Adjust restart (voltage or %)
Activating Shutdown causes the inverter to enter standby-mode. It does not com-
pletely shut down the inverter. Total shutdown occurs at voltages below 19V.
The voltage displayed on the Sunsynk Parity Inverter will vary depending on whether the inverter
is charging or discharging the batteries.