Page | 47
Hybrid Inverter | Installer Manual
5.11. Generator & Battery Page
To configure battery charging settings, click on the BATTERY icon and then on ‘Batt Charge’.
What this page displays:
Generator start voltage/SOC %.
Grid power start voltage/SOC %.
Float V is the voltage at which a battery is maintained after being fully charged.
Absorption V the level of charge that can be applied without overheating the battery.
Float V for an AGM battery is 55.20V.
Absorption V is for an AGM battery is 57.60V.
Equalization V for an AGM battery is 58.80V.
Equalizing charge/overcharge to remove sulphate crystals that build-up on the plates over
time on lead-acid batteries.
What you can do from this page:
Tick ‘Gen Charge’ to charge the batteries from the gen I/P.
Tick ‘Grid Charge’ to charge the batteries from the grid I/P.
Tick ‘Gen Signal’ signal to auto-switch a relay box.
Tick ‘Grid Signal’ signal to auto-switch a relay box.
Do not alter these settings too many times on the same battery as it may damage
the battery.
Summary of Contents for SUNSYNK-8K-SG01LP1
Page 9: ...2 1 Product Size Page 9 Hybrid Inverter Installer Manual Inverter Size...
Page 16: ...Page 16 Hybrid Inverter Installer Manual 4 5 Function Port Definition...
Page 20: ...Page 20 Hybrid Inverter Installer Manual...
Page 22: ...Page 22 Hybrid Inverter Installer Manual 4 9 1 Recommended AC Surge Protector...
Page 28: ...Page 28 Hybrid Inverter Installer Manual 4 13 Wiring System for Inverter...
Page 29: ...Page 29 Hybrid Inverter Installer Manual...
Page 34: ...03 02 01 Page 34 Hybrid Inverter Installer Manual...
Page 37: ...Page 37 Hybrid Inverter Installer Manual 4 19 2 Connected to a Generator 03 02 01...