SunSynk SUNSYNK-8K-SG01LP1 Installer Manual Download Page 1

  

 

 
 

 

 

 

 

 

 

 

HYBRID PARITY 

(SUPER) INVERTER

SUNSYNK-8K-SG01LP1 / SUNSYNK-8K-SG03LP1 

INSTALLER MANUAL

v.11 (03/30/22)

Global Tech China Ltd, 3 Floor, Wai Yip Industrial Building.

171 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong.

Tel: +852 2884 4318 Fax: +8522884 4816

www.sunsynk.com / [email protected]

Summary of Contents for SUNSYNK-8K-SG01LP1

Page 1: ...SG01LP1 SUNSYNK 8K SG03LP1 INSTALLER MANUAL v 11 03 30 22 Global Tech China Ltd 3 Floor Wai Yip Industrial Building 171 Wai Yip Street Kwun Tong Kowloon Hong Kong Tel 852 2884 4318 Fax 8522884 4816 ww...

Page 2: ...ll be displayed on the inverter screen the LED indica tor fault will light up SUNSYNK 8K SG01LP1 SUNSYNK 8K SG01LP3 Australia Main Dealer HORTON SOLAR CONSULTING Pty Ltd 166a King William Road HYDE PA...

Page 3: ...d AC Surge Protector 22 4 10 Installing the CT Coil 23 4 11 Earth Connection MANDATORY 25 4 12 Meter Connection 26 4 12 1 System Connection for the CHNT Meter EU 26 4 12 2 System Connection for the Ea...

Page 4: ...age 50 5 13 Setting Up a Lithium Battery 52 5 14 Program Charge Discharge Times 57 5 15 Grid Supply Page 60 5 16 Connecting the DRM s 61 5 17 Advanced Settings for Paralleling Inverters 62 5 18 Solar...

Page 5: ...mpairment that would affect their ability to follow this manual install maintain or repair this device Any untrained personnel who might get near this device while it is in operation MUST be informed...

Page 6: ...k of electrical shock The unit is not explosion proof so it should not be installed in an explosive atmosphere Never touch electrical components immediately after the power supply has been turned off...

Page 7: ...ines 220V single phase pure sinewave inverter Self consumption and feed in to the grid Auto restart while AC is recovering Auto earth bond feature Via a relay CONFIGURABLE Fully programmable controlle...

Page 8: ...cators 7 CAN Port 13 Grid 2 LCD Display 8 Battery input connectors 14 Generator input 3 Function Buttons 9 Function Port 15 Load 4 DC Switch 10 Meter_CON port 16 WiFi Interface 5 Power on off button 1...

Page 9: ...2 1 Product Size Page 9 Hybrid Inverter Installer Manual Inverter Size...

Page 10: ...ntegrator for other possible system architectures depending on your requirements This inverter can power all kinds of appliances in home or once environment including mo tor type appliances such as re...

Page 11: ...ty Interactive AC Output Voltage L N PE 220 230Va c AC Output Frequency 50 60Hz AC Output Rated Current 36 4Aa c Max AC Output Current 40Aa c max Max AC Output Power 8800W AC Output Rated Power 8800VA...

Page 12: ...ION 4 1 Parts List Check the equipment before installation Please make sure nothing is damaged in the package You should have received the items in the following package Page 12 Hybrid Inverter Instal...

Page 13: ...ct the equipment such as sulphuric gas chlorine gas acid or alkali These can cause the copper pipes and brazed joints to corrode and fail to conduct electricity reliably Areas that can cause combustib...

Page 14: ...r unit on the wall where the height from the floors is higher than 1600mm For proper heat dissipation allow a clearance of approximately 500mm to the side 500mm above nd below the unit and 1000mm to t...

Page 15: ...Choose the recommend drill head as shown in below pic to drill 4 holes on the wall 52 60mm deep 1 Use a proper hammer to fit the expansion bolt into the holes 2 Carry the inverter and holding it make...

Page 16: ...Page 16 Hybrid Inverter Installer Manual 4 5 Function Port Definition...

Page 17: ...the battery terminals 2 Use a suitable screwdriver to unscrew the bolts and t the battery connectors in then fas ten the bolt by the screwdriver make sure the bolts are lightened with torque of 5 2 N...

Page 18: ...losing the DC Breaker disconnection device ensure the inverter unit is wired correctly A reverse polarity connection on the battery will damage the inverter 4 6 1 Recommended DC Battery Protection Pag...

Page 19: ...ery Temperature Sensor Connection Without a remote temperature sensor lead acid batteries may undercharge or overcharge de pending on the ambient temperature of the installation environment This may r...

Page 20: ...Page 20 Hybrid Inverter Installer Manual...

Page 21: ...rrect terminals and ensure the wires are securely connected Model Wire Size Cable mm2 Torque value max 8kW 10AWG 8 1 2N m All wiring and cable sizes must comply with your particular country s wiring r...

Page 22: ...Page 22 Hybrid Inverter Installer Manual 4 9 1 Recommended AC Surge Protector...

Page 23: ...ower to the grid This feature is also known as Zero Export 1 Fit the coil sensor around the live cable on the main fuse feeding the building and run the cable back to the inverter This cable can be ex...

Page 24: ...r Manual If the CT coil is fitted in the wrong way then this variable will have negative instead of positive val ues when the power is flowing into the house inverter Also the inverter export limiting...

Page 25: ...n cause faults with an RCD before the inverter Since the inverter is a true hybrid then the bond must only be made when the inverter is oper ating in Islanding Mode To accommodate this Sunsynk provide...

Page 26: ...4 12 Meter Connection 4 12 1 System Connection for the CHNT Meter EU 4 12 2 System Connection for the Eastron Meter EU Page 26 Hybrid Inverter Installer Manual...

Page 27: ...Page 27 Hybrid Inverter Installer Manual 4 12 3 System Connection for the CHNT Meter US 4 12 4 System Connection for the Eastron Meter US...

Page 28: ...Page 28 Hybrid Inverter Installer Manual 4 13 Wiring System for Inverter...

Page 29: ...Page 29 Hybrid Inverter Installer Manual...

Page 30: ...ion When selecting the PV modules you should consider the following parameters 1 Open Circuit Voltage Voc of PV modules does not exceed the maximum PV array Voc 2 Open Circuit Voltage Voc of PV module...

Page 31: ...Page 31 Hybrid Inverter Installer Manual 4 14 3 PV Protection 4 15 Typical Application Diagram of Diesel Generator...

Page 32: ...4 16 Single Phase 230Vac Parallel Connection Diagram Page 32 Hybrid Inverter Installer Manual 03 02 01...

Page 33: ...Page 33 Hybrid Inverter Installer Manual 4 17 Split Phase 120 240Vac Parallel Connection Diagram 03 02 01...

Page 34: ...03 02 01 Page 34 Hybrid Inverter Installer Manual...

Page 35: ...4 18 Three Phase 230 400Vac Parallel Connection 03 02 01 Page 35 Hybrid Inverter Installer Manual...

Page 36: ...Page 36 Hybrid Inverter Installer Manual 4 19 Three Phase 120 208Vac Parallel Connection 4 19 1 Connected to the Grid 03 02 01...

Page 37: ...Page 37 Hybrid Inverter Installer Manual 4 19 2 Connected to a Generator 03 02 01...

Page 38: ...Page 38 Hybrid Inverter Installer Manual 4 20 Three Phase 120 208Vac PCs Parallel Connection 02 01...

Page 39: ...LED solid light Grid connection normal Normal Green LED solid light Inverter functioning normally Alarm Red LED solid light Fault Function Key Description Esc To exit the previous mode Up Increase th...

Page 40: ...0 0 kWh 0 0 kWh 0 0 kWh 0 0 kWh 85 BATTERY IN OUT MPPT GRID SOLAR TURBINE AC load Battery Grid 1 Customer name 2 Access settings menu page 3 Access solar history 4 Access system status page 5 Access...

Page 41: ...positive If the sign of the grid and HM home powers are not the same when the PV is disconnected and the inverter is only taking energy from the grid and using the CT connected to Limit 2 then please...

Page 42: ...ure bellow 1 The PV modules charge the batteries 2 When the batteries reach a specific level programmable the battery power is fed into the inverter 3 The inverter can then supply power to the grid ex...

Page 43: ...m mode press the SYSTEM MODE icon Access the advanced settings such as Paralleling and Wind Turbine press the ADVANCE icon Access the auxiliary load smart load settings press the AUX LOAD icon Access...

Page 44: ...LCD backlight to auto dim 0 0 kWh 0 0 kWh 0 0 kWh 0 0 kWh 0 0 kWh 0 0 kWh 85 BATTERY IN OUT MPPT GRID SOLAR TURBINE AC load Battery Grid How to change the name Change the letters in each box by mov i...

Page 45: ...annot be reset Before performing a successful Factory Reset and locking the systems the user must enter a password to allow the setting to take place The password for Factory Reset is 9999 and for loc...

Page 46: ...ttery manufacturer documentation Note This is a global max discharge current for both grid tied and backup modes of operation and if the cur rent exceeds this value inverter will shut down with an ove...

Page 47: ...he battery Float V for an AGM battery is 55 20V Absorption V is for an AGM battery is 57 60V Equalization V for an AGM battery is 58 80V Equalizing charge overcharge to remove sulphate crystals that b...

Page 48: ...e Grid side or to the Gen connection When connect ed to the Grid Input the inverter will consider the power coming from the generator as Grid Supply Users should make sure this power goes to the LOAD...

Page 49: ...Page 49 Hybrid Inverter Installer Manual...

Page 50: ...a voltage or Restart voltage set as either a voltage or What you can do from this page Adjust battery shut down voltage or Adjust low battery warning voltage or Adjust restart voltage or Activating S...

Page 51: ...voltage is needed This period of the charging process is called absorption This occurs when the charging of a battery has reached reached 80 of its capacity The remaining charge equals 20 approxi mat...

Page 52: ...the Lithium option is selected under Batt Type The type of communion protocol Approved batteries What you can do from this page Set up you Lithium ion battery After installing a lithium battery check...

Page 53: ...pproved by Sunsynk With some types of lithium battery the BMS cannot be controlled by the Sunsynk inverter In this case treat the battery as a lead acid type and set the charging and discharging proto...

Page 54: ...oda H4850M RS485 7 VISION Group V LFP51 2V100Ah 5KW CAN 13 VLFP51 2V200Ah 5KW CAN 13 Alpha Ess M4856 P CAN 0 SMILE BAT CAN 0 GSL ENER GY GSL051100A B GBP2 CAN 0 GSL051200A B GBP2 CAN 0 GSL051280A B GB...

Page 55: ...00 RS485 16 Deye SUNB 5 0 C01 48 PC CAN 0 SUNB 5 0 E01 48 PC CAN 0 SUNB 5 0 G01 48 PC CAN 0 AOBOET Uhome LFP 5000 CAN 0 Uhome LFP 2400 CAN 0 Wattsonic Li LV battery series CAN 14 KODAK FL5 2 CAN 0 Fox...

Page 56: ...facturer are followed If you are using lead acid batteries then follow the equation of C x 0 25 which means that the maximum charge or discharge you can apply to a battery is a quarter of the AH ratin...

Page 57: ...hold loads Solar Export Set the power limits to supply only the loads connected to the LOAD port Priority to Load Only What you can do from this page Set a real time to start and stop charging or disc...

Page 58: ...side of the inverter 4 Zero Export Power is the amount of power flowing from the Grid to the Inverter Set this value to 20 100W to instruct the inverter to always take the prescribed amount of pow er...

Page 59: ...Setup Home Page If the Use Timer function is activated then the inverter will use the battery power according to your settings when the Grid is present If this function is not set the batteries WILL O...

Page 60: ...Grid type normally 230V three phase What you can do from this page Set the Minimum Grid Input Voltage Grid Vol Low Set the Maximum Grid Frequency Grid Hz High Set the Minimum Grid Frequency Grid Hz L...

Page 61: ...rter Installer Manual 5 16 Connecting the DRM s This can be selected under advance settings This can be selected under advance settings 1 DRM 1 5 2 DRM 2 6 3 DRM 3 7 4 RDRM 4 8 5 Ref 0 6 D Ground 7 Ne...

Page 62: ...hich the inverter will be paralleled Set the Modbus SN for paralleling The Sunsynk parity inverter can be wired standalone or where more power is required it can be connected in parallel either single...

Page 63: ...rs to the latest and the exact same firmware version IMPORTANT All inverters in a parallel system must have their own isolating load breaker before it goes to the parallel breaker to ensure while prog...

Page 64: ...quences of not setting one inverter in a parallel mode It can damage the inverter Q4 What are the consequences of having more than one Master Inverter or having no inverter set as Master It can damage...

Page 65: ...rly and total solar power produced Access this page by clicking on the Solar Turbine icon on the Home Page 5 19 Grid Power This page shows the Daily Monthly Yearly and total grid power export or consu...

Page 66: ...w shows the maximum current depending on the voltage of the wind turbine DO NOT use a wind turbine that exceeds 400V Use a self breaking wind turbine Once the batteries are fully charged and the inver...

Page 67: ...unt the output Most wind turbines are three phase PM type Therefore either a wind turbine controller or a direct connection to the MPPT via a simple protection circuit will be required 5 21 Advanced S...

Page 68: ...4kW Zero Export Tick this box to stop exporting power produced by the Aux Load Gen Peak Shaving Tick this box to use peak power shaving 5 22 Advanced Settings for Peak Shaving To configure Peak Power...

Page 69: ...nverter 3 On grid Power Generation Date 4 The problem description including the fault code and indicator status displayed on the LCD with as much detail as possible 5 Owner s contact information Error...

Page 70: ...les are correctly connected F42 AC line low voltage Grid voltage fault 1 Check if the voltage is in the range of standard voltage in specification this can be adjusted via the grid set up page 2 Check...

Page 71: ...OverCurr_Failure F46 AC_UV_UnderVolt_Fault F15 AC_OverCurr_Failure F47 AC_OverFreq_Fault F16 GFCI_Failure F48 AC_UnderFreq_Fault F17 Tz_COM_OC_Fault F49 AC_U_GridCurr_DcHigh_Fault F18 Tz_Ac_OverCurr_F...

Page 72: ...ncerning safety and electromagnetic compatibility Before leaving the factory all inverters undergo rigorous testing to ensure the inverter can operate reliably as presented in Chapter 3 Technical Spec...

Page 73: ...tallation engineer must have completed the Earth Bond RCD and earth leakage tests checked that the solar panel Voc voltage does not exceed 480V and checked the battery voltage Power ON Sequence 1 Swit...

Page 74: ...harge is within the C rating of the battery Too high will damage the battery Check the battery BMS is communicat ing with the inverter This is the heart of the system this controller everything Ensure...

Page 75: ...ce a year for dusty environments this may need to be carried out weekly all the cooling fans air ducts are cleaned and dust free Check if there are no fault codes and Lithium battery communication is...

Page 76: ...S NZS3000 for the cable from the switchboard to the IES If an RCD is installed the engineer must 1 Disconnect all live conductors including both active and neutral conductors and 2 Be of the type spec...

Page 77: ...nnection for the Data Logger please refer to the App User instructions The Data Logger should be connected to the bottom of the inverter via the connection socket marked WIFI For more information trai...

Page 78: ...g 171 Wai Yip Street Kwun Tong Kowloon Hong Kong Tel HK 852 2884 4318 Fax 852 2884 4816 Tel UK 44 151 528 9945 Tel SA 27 1108 39837 sales globaltech china com Audio Training manuals on Apple Pod Cast...