24
(3) Setting Pattern Data Call Function
You can inactivate calling unnecessary patterns. This prevents calling wrong patterns by mistake and helps you call the
necessary patterns.
(4) Setting the Counter Function
A. Turn on the memory switch and press
to display
“A-03” on the screen.
B. Press
to display the present set-up value.
ⓐ
part : pattern number
ⓑ
part : 0 :calling impossible
ⓑ
part :
1 :calling possible
C. Press
to change “1” in
ⓑ
to “0”.
D. Press
to change “1” in
ⓐ
to “2”
E. Press
to change “1” in
ⓑ
to “0”.
F. Register the set-up using
.
READY
–/BACK
SELECT
–/BACK
READY
+/FORWARD
Ex) Inactivating calling of patterns 1 and 2
ⓐ
ⓑ
A - 0 3
0 2 - 1
0 1 - 1
0 1 - 0
A - 0 3
0 2 - 0
Ex) Changing production counter (addition mode) to lower thread counter (reduction mode)
A. Turn on the memory switch and press
to display
“A-05” on the screen.
B. Press
to display the present set-up value.
C. Press
to set “05-1”.
ⓐ
part : 0 : production counter
ⓐ
part :
1 : lower thread counter
D. Register the set-up using
.
READY
+/FORWARD
READY
+/FORWARD
ⓐ
A - 0 5
A - 0 5
0
1