26
6-3) Memory Switch Functions Table
(1) General sewing functions (A Group)
Turn on the power pressing
and
. Turn on the memory switch pressing
.
P1
General: 100~3,200
2,700
spm
Heavy: 100~3,200
2,700
spm
Light: 100~2,700
2,300
spm
A-01
Setting maximum sewing speed
Knitwear:
100~2,700
2,300 spm
100spm
Buttons: 100~2,700
2,300
spm
Hole fixing :
100~3,200
2,700 spm
1st stitch: 400~900
400 spm
2nd stitch: 400~2,000
900 spm
A-02
Setting speed for the first 1-5 stitches
3rd stitch: 400~2,000
2,300 spm
100spm
(Softstart function, different by type)
4th stitch: 400~2,000
2,300 spm
5th stitch: 400~2,000
2,300 spm
A-03
Setting pattern data calling
0 : calling impossible
(You can set for each pattern)
1 : calling possible
A-04
Setting display and change possibility of X,Y scale
0 : change impossible
1
rate and maximum speed limit (prevent errors or mistakes)
1 : change possible
Setting counter function
0 : production counter
A-05
Production counter : addition count
0
Lower thread counter : reduction count
1 : lower thread counter
A-06
Setting center point for scale
0 : original point
0
1 : sewing start point
A-07
Setting whether to search original point after sewing
0 : OFF
0
(sewing with ordinary pattern number)
1 : ON
A-08
Setting whether to search original point after sewing
0 : OFF
0
(sewing with function combination)
1 : ON
A-09
Setting drive scope to infinite
0 : Infinite
1
1 : limited
A-10
Setting starting angel for X, Y drive
–100 ~ 100
°
Belt type : –24
°
, Direct : –24
°
1
°
A-11
Setting trimming speed
200 ~ 400spm
400 spm
100spm
A-12
Setting reverse rotation after trimming
0 : OFF, 1 : ON
0
A-13
Setting angle for reverse rotation after trimming
0~70
°
0
°
1
°
A-14
Setting whether to use electronic wiper
0 : OFF
1 : ON
A-15
Faster moving of presser foot after trimming
0 : OFF, 1 : ON
1
A-16
Setting search for original point after certain amount of sewing
0 : OFF
0
(after amount set in A-17)
1 : ON
A-17
Number of automatic search for original point
0~1000
1000
4
A-18
Time for electronic wiper ON
4~1024 ms
100 ms
4 ms
A-19
Canceling trimming
0 : trim ON
0
1 : trim OFF
A-20
Time for solenoid 0 full on (clamp solenoid)
4~72 ms
52 ms
4 ms
A-21
Time for solenoid 1 full on (trimming solenoid)
4~1020 ms
100 ms
4 ms
A-22
Time for solenoid 2 full on (sub solenoid 2)
4~1020 ms
100 ms
4 ms
A-23
Time for solenoid 3 full on (sub solenoid 3)
4~1020 ms
100 ms
4 ms
A-24
Solenoid 0 duty (clamp solenoid)
10~25%
10%
1%
A-25
Solenoid 1 duty (trimming solenoid)
10~25%
20%
5%
A-26
Solenoid 2 duty (sub solenoid 2)
10~25%
20%
5%
A-27
Solenoid 3 duty (sub solenoid 3)
10~25%
20%
5%
A-28
Delay time for clamp solenoid moving up
-
-
-
A-29
Delay time for clamp solenoid moving down
A-30
Setting OFF time for electronic wiper
4~1020 ms
4 ms
A-31
Setting whether clamp moves up/down after mid trimming
0 : Down, 1 : Up
1
A-32
Setting pneumatic thread holder
0 : OFF, 1 : ON
0
A-33
Setting integrated/separated pedal
-
-
(For pneumatic only. Others have integrated pedals)
A-34
Setting whether to use pin hole device
0 : OFF
1 : ON
A-35
Setting whether to use head open/close
0 : OFF
1 : ON
A-36
Whether to use upper stop when turn power on
0 : OFF
1 : ON
A-37
Set time for AC off checking
4 ~ 48 [ms]
20 ms
A-38
Set time for voltage overload checking
4 ~ 1024 [ms]
20 ms
No.
Functions and Description
Scope
Default
Unit
1201
1~22 : 1
23~99 : 0
1~33 : 1
34~99 : 0
1~56 : 1
57~99 : 0
1202
1254
1201, 1202
Others
Hole fix device
40 ms
100 ms
Others
Only in Direct type
Only in Direct type
1
1
Hole fix device
0
1
0
1
1254