11
[Figure 3]
3) Oil supply
(1) Installing chip remover magnet
Attach the magnetic chip remover
①
that is in the accessory
box to the oil fan. (See Figure 3.)
※
Do not use the magnet for other purposes. Use of the sewing
machine without the magnet may cause malfunction and has
a bearing on the machine
’
s durability.
(2) Lubricating the oil fan
A. Fill the lubricant up to the
“
HIGH
”
mark. (See Figure 3.)
B. The lubricant must be SUNSTAR’s oil provided exclusively
for industrial sewing machines or SHELL’s Tellus C10.
C. If the oil in use is down to the
“
LOW
”
mark, fill in to
“
HIGH
”
immediately.
D. Once every two weeks is deemed the appropriate
interval for oil refills.
Caution
▶
Plug in only after oil supply is finished. If the operator mistakenly steps on the pedal with
the plug in, the machine will start automatically and can cause severe injuries.
▶
When handling lubricants, wear protective glasses or gloves to avoid contact with your
eyes or skin. Inflammation may be caused otherwise. Never drink lubricants since they
can cause vomiting or diarrhea. Keep out of the reach of children.
▶
Operate the machine only after adding oil when the machine is being used for the first time
or has been left unused for a long time.
[Figure 4]
(3) For new machines that have been delivered a long ago or has not been used for a long period of time, open the face plate
and apply the oil spray 2-3 times to friction areas such as the thread take up lever linkage
①
, the needle bar
②
and the
presser bar
③
. (See Figure 4.)