20
Adjusting the auxiliary presser foot
※
Loosen the pressure-adjusting screw
④
and the bracket-fastening screw
⑤
.
※
Adjust the bracket-fastening screw
⑤
so that the auxiliary presser foot
①
rise about 10.5 mm from the needle plate
top when the pressure lifter
③
is raised.
(After adjustment, be sure to fasten the bracket-fastening screw
⑤
first, and then adjust the pressure-adjusting
screw
④
.)
※
Affter the adjustment of the height of the auxiliary presser foot
①
, adjust the upper feed presser foot
②
.
Adjusting the upper feed presser foot
※
Loosen up and down crank clamp screw
⑥
when the pressure lifter
③
is down.
※
Move the needle bar close to its highest position.
※
Adjust the height of the upper feed presser foot
②
to the sewing materials.
(2) Adjusting the height of the strokes of both different
[Figure 31]
②
①
⑥
④
⑤
③
10.5mm
Summary of Contents for KM-570BL