44
The "More" screen supports the following operations:
•
Set parameters including inverter operation parameters, protection parameters, and
power regulation.
•
Upgrade inverter firmware (ARM/DSP/PVD/CPLD).
7.7.1 Operation Parameters
A
Ac
cttiivve
e &
& rre
ea
ac
cttiivve
e p
po
ow
we
err p
pa
arra
am
me
ette
errss
table 7-3
Description of Active & reactive power parameters
P
Pa
arra
am
me
ette
err
D
De
essc
crriip
pttiio
on
n
D
De
effa
au
ulltt
R
Ra
an
ng
ge
e
Pac Limit
Inverter active power
limitation
110.0%*
0~110%
Speed control
Set whether to enable speed
control
[OFF]
[OFF]/ [ON]
Active power
ascent speed
-
100%/min
8~6000%/min
Active power
descent speed
-
6000%/min
8~6000%/min
Fault slow start
Set whether to enable fault
slow start
[OFF]
[OFF]/ [ON]
Power increase
speed
-
100%/min
8~100%/min
Reactive
adjusting switch
-
[OFF]
[OFF]/ [Pf] [Qt]
[Q(p)] [Q(u)]
PF
-
1.000
-1000~-800/
800~1000(Unit
0.001)
Reactive power
limit
Inverter reactive power
limitation
0.0%
-100%~100%
Active setting
keep
Set up whether to perpetually
save the active power
settings or not
[OFF]
[OFF]/ [ON]
Limited power
-
[ON]
[OFF]/ [ON]
Reactive setting
keep
Set up whether to perpetually
save the reactive power
settings or not
[ON]
[OFF]/ [ON]
* The default value for some devices is 100.0%.