66
P
Pa
arra
am
me
ette
errss
S
SG
G1
10
0K
KT
TL
L--M
M
S
SG
G1
12
2K
KT
TL
L--M
M
Max. current for input
connector
15 A
Max. DC short-circuit current
30 A(15 A / 15 A)
Max. inverter backfeed current
to the array
0 A
O
Ou
uttp
pu
utt ((A
AC
C))
AC output power
10000VA*/11000 VA
@35 ℃/ 10000 VA @ 45
℃
13200VA @ 35
℃/12000 VA @ 45 ℃
Max. AC output current
16.5 A
20 A
Nominal AC voltage
3 / N / PE, 230 / 400 V
AC voltage range
270 ~480 V
Nominal grid frequency
50 Hz / 60 Hz
Grid frequency range
45 ~ 55 Hz / 55 ~ 65 Hz
THD
< 3 % (at nominal power)
DC current injection
< 0.5% In
Power factor at nominal power
> 0.99
Adjustable power factor
0.8 leading ~ 0.8 lagging
Feed-in phases / Connection
phases
3 / 3
E
Effffiic
ciie
en
nc
cyy
Max. efficiency
98.60%
Euro. efficiency
98.10%
P
Prro
otte
ec
cttiio
on
n
LVRT
Yes
Islanding protection
Yes
DC reverse connection
protection
Yes
AC short-circuit protection
Yes
Leakage current protection
Yes
Grid monitoring
Yes
User Manual