Before Starting Your Heater

Before  you  start  your  heater  examine  the  heater 
installation to determine that:

Areas  immediately  around  the  heater  including 
the  air  inlet  and  flue  areas  are  free  from 
obstructions.

Physical support of the heater is sound.
There is no obvious deterioration of the heater.
Portable type heaters must be place  on level and 

adequate footing.

Starting and Shutting Down Your Heater

Sunglo  heaters  can  utilize  a  variety  of  gas  control 
systems. With some models it is necessary to light a 
pilot while other models have a fully automatic ignition 
system. Identify the model of your heater on the Basic 
Lighting  Instructions  chart  on  page  6  and  follow  the 
lighting instructions. If heater fails to light or does not 
heat properly discontinue use of the heater and contact 
your local distributor, or qualified service agency.

Performing Routine Maintenance

Overtime, particularly during long periods of disuse, the 
heater can accumulate dirt and debris in and around 
the pilot and the burner.  Routine maintenance should 
be performed at least once a year by a qualified service 
agency to insure the heater is operating properly. More 
frequent service may be required for heaters located 
near waterfronts.

agency  to  insure  that  clearances  from  combustible 
material and ventilation requirements are maintained 
after alterations are complete.  When plastic curtains or 
drops are used to enclose a patio you must take steps 

 

to insure that all Sunglo™ heaters have the required 
permanent  access  to  outside  air.  If  a  patio  is  to  be 
partially enclosed a qualified agency familiar with this 

 

type of heating equipment must be consulted to insure 

 

the safe operation of this equipment. 

 

d

Warning Labels

It is important that warning labels including the lighting 
instruction are not removed from the heater.   If labels 
are  damaged,  replacement  labels  are  available  from 
your local dealer or the factory.

Stainless Steel Care

Stainless  steel  does  not  “rust”;  however  air  pollution 
can leave brown deposits on heaters. We recommend 
washing the stainless steel post and base only with a 
mild detergent solution and wiping it dry with a soft cloth 
to bring back the original shine. The stainless steel may 
be expected to permanently darken around the top of 
the heater.

Before You Remodel

Should you plan to make any changes to the patio or 
building  structure  after  heaters  have  been  installed, 
your heater installation must be reviewed by a qualified 

Basic Lighting with Sunglo

 Manual Control

(See lighting instructions pertaining to your heater 

model on page 6.)

Sunglo  Infrared Heaters

OWNER’S MANUAL

PROP. 65 CARBON MONOXIDE

 

WARNING!

If  not  installed,  operated  and  maintained  in 
accordance  with  manufacturer’s  instructions, 
this product could expose you to substances in 
the fuel or from combustion, including Carbon 
Monoxide,  which  can  cause  death  or  serious 
illness,  and  which  are  known  to  the  State  of 
California  to  cause  cancer,  birth  defects  or 
reproductive harm.

WARNING

5

Summary of Contents for A242

Page 1: ...ling or servicing this equipment P N 65132 8 08 Copyright 2008 By Infrared Dynamics Inc Printed in USA TO THE INSTALLER Please read and understand all instructions prior to installation Give a copy of this manual to the owner after installation TO THE OWNER Keep this manual in a safe place in order to provide your serviceman with the necessary information Installation and replacement of gas piping...

Page 2: ...ocate Patio Heaters 7 Using Multiple heaters 7 Section 4 Installation 8 Receiving Equipment 8 Code Requirements 8 Gas Supply 8 Clearance Requirements 8 Fire Sprinklers 9 Electrical 9 Ventilation 9 Gas Piping 9 Initial Start Up 9 Section 5 Heater Models 10 PSA65 and PSA265V 10 A242 Post and Base 13 A244 and A244V 15 PSA265E and A244E E Series 17 Section 6 Maintenance and Trouble Shooting 19 Sunglo ...

Page 3: ...nsult your local Fire Marshall insurance carrier and other authorities for approval of the proposed installation Sunglo heaters are designed and certified for commercial indoor outdoor and residential outdoor applications and are NOT approved for use in any indoor residential application This includes but not limited to attached garages living quarters solarium etc Consult the local Not For Indoor...

Page 4: ...safety the building must be evaluated for hazards before installing the heater system including the following Acritical safety factor to consider before installation is the clearance to combustible materials Clearance to combustible is defined as the minimum distance you must have between the heater casing and the combustible items Consideration must also be made for moving objects around the infr...

Page 5: ...ps are used to enclose a patio you must take steps to insure that all Sunglo heaters have the required permanent access to outside air If a patio is to be partially enclosed a qualified agency familiar with this type of heating equipment must be consulted to insure the safe operation of this equipment d Warning Labels It is important that warning labels including the lighting instruction are not r...

Page 6: ...hting pilot To Turn Heater ON 1 Turn the gas valve ON 2 Turn ON Electrical Switch 24 VAC only To Turn Heater OFF 1 Turn the electrical power OFF 2 Turn the gas valve OFF Warning If burner fails to ignite shut OFF electrical power and wait 5 minutes before repeating lighting process Warning DO NOT attempt to light this heater manually MANUAL CONTROL This heater utilizes a standing pilot with thermo...

Page 7: ...rmed to enhance the direct 1 With walls on all sides but with no heating the patio radiant warming effect overhead cover Breezy Conditions 2 Within a partial enclosure which TM Sunglo heaters are designed to includes an overhead cover and no work well under a variety of outdoor more than two side walls These conditions however under certain side walls may be parallel as in a conditions they work b...

Page 8: ...priate license The stated clearance to combustible materials Persons not qualified shall not attempt to install this represents a surface temperature of 90ºF 32ºC above equipment nor attempt repairs room temperature Building materials with low heat tolerance may be subject to degradation at lower Code Requirements temperatures It is the installer s responsibility to assure that adjacent materials ...

Page 9: ... gas inlet piping The electrician should supply a connection box as shown adjacent to the heater electrical inlet and run rigid waterproof conduit up to the right just inside the frame channel WARNING The minimum fire hazard clearance marked on the heater must be maintained from vehicles parked below the heater The electrical input required to the heater is 0 550 Amps at 24V rated at 8 Watts A 4OV...

Page 10: ...st Sunglo Infrared Heaters Part No 35031 80023 80036 8003 70036 70055 70059 Item 1 2 3 4 5 6 7 Description Frame PH Hanging Elbow 1 2 Nipple 1 2 X 16 1 2 Nipple 1 2 X Close Bolt 3 8 X 2 1 2 Hex Washer 3 8 SAE Zn Nut 3 8 16 Hex Zn 16 ...

Page 11: ...32 x 3 8 3 70038 Nut 8 32 4 30623 3 lgnitor Cover 5 70072 Screw 8 32x 1 288 6 30623 Bracket A270 Ignitor 7 30629 Plate Ignitor Ground 8 90072 Battery AA 1 5 Volt 9 90071 Ignitor BP E1 10 70066 Screw 10 24x 250L 11 30204 5 Cylinder PH Perf SS Item not shown DSI OPTIONAL SPARK IGNITION SYSTEM 20 ...

Page 12: ...ER DISASSEMBLY Tools Required WARNING TM Repair and maintenance of Sunglo Heaters must be performed by a qualified service technician Reassembled heater must be thoroughly checked for leaks and checked for proper operation before use 21 ...

Page 13: ...r should be in good condition and free of dust and debris Make sure the heater is mounted securely and there is no corrosion or damage to the post or mounting brackets Inspect emitter grid for cracks or bubbles Using a wire brush remove any soot scale or debris from the inside of the emitter grid Check the gas line for leaks using soapy water at all joints and connections Light heater to verify pr...

Page 14: ...se wire l Spark will not light pilot No gas to pilot l Electrode not sparking to pilot hood l Improper electrode gap 3 16 l Main burner does not light No power to the heater 24 VAC l Control knob not in On position l No Spark to Electrode Improper electrode gap 3 16 l Damaged electrode or wiring l Damaged ground wire l No gas to pilot l Gas Valve does not open No power to the heater 24 VAC l Loose...

Page 15: ...d defective heater or part to such distributor C All cost necessary or incidental for handling and administrative charges and for any material and or permits required for installation of the replacement heater or part LIMITATION ON IMPLIED WARRANTIES Implied warranties including any warranty of merchantability imposed on the sale of this heater under state law are limited to one year duration for ...