Thank you for choosing Sunforce Products Pro Series Pure Sine Wave Inverters. Our inverters
have been carefully engineered and manufactured to give you a dependable power source. A
Pure Sine Wave Inverter converts low voltage, direct current (DC) to 110 volt alternating
household current (AC) depending on the model and its rated capacity. Pure Sine Wave Inverters
draw power, either from standard 12 volt automobile and marine batteries, or from portable high
power 12 volt sources.
Please read this manual thoroughly before operating your new Inverter. Pay close attention to
any WARNING and CAUTION notes. This will help you to receive the best possible performance
from your new inverter.
1.
Important Safety Precautions
2. Important
Cable
Information
3.
About the Circuit Breaker
4.
Full Load AC Output
5. Getting
Started
6.
Features of the Sunforce Products Pro Series Pure Sine Wave Inverter
7.
Connecting your Inverter
8.
Source of Power
9. While
in
Use
10.
Remote Control
11. LCD
Display
12. Trouble
Shooting
IMPORTANT SAFETY PRECAUTIONS
Working with Batteries
•
RISK OF EXPLOSIVE GAS – Working in the vicinity of a lead acid battery is dangerous.
Lead acid batteries produce hydrogen-gas when charging that can cause explosion and
sulfuric acid that can cause severe burns. Always charge batteries and work in a well-
ventilated area.
•
DO NOT SMOKE, OR ALLOW A SPARK OR A FLAME IN THE VICINITY OF A BATTERY!
•
Remove personal metal items such as rings, necklaces, watches, and bracelets when
working with a battery. Be extra cautious not to drop a metal wrench onto the battery,
bridging the terminal posts. The battery may spark and short circuit, and explode.
•
Be careful when making connections not to bridge the terminals with a wrench at the rear
of the inverters as the terminal posts are close to one another, and could result in a short
circuit.
•
NEVER CHARGE A FROZEN BATTERY
•
If battery acid contacts skin or clothing, wash immediately with soap and water. If acid
enters the eye, IMMEDIATELY FLOOD EYE WITH RUNNING COLD WATER for at least
10 minutes. GET MEDICAL ATTENTION IMMEDIATELY.
Failure to comply with above warnings may lead to explosion, and or severe injury.
Is the Battery Fully Charged?
State of battery can be determined by Hygrometer testing of electrolite in the battery, or the
voltage of the battery as measured with no load and a good quality digital voltmeter.
See the table below