background image

 

 

KYOCERA Assembly and Maintenance Instructions, November 2014

 

 

 

SOLAR MODULES 

Assembly and Maintenance Instructions, November 2014

 

KK-Series: KK255P-3CB2CG

 

 

Contents 

1

 

About these instructions ....................................... 1

 

2

 

Description of the solar modules .......................... 1

 

3

 

Safety ....................................................................... 2

 

4

 

Assembly................................................................. 2

 

5

 

Electrical connection ............................................. 3

 

6

 

Maintenance ............................................................ 4

 

7

 

Disclaimer ............................................................... 4

 

8

 

Customer service / Contact ................................... 4

 

 

About these instructions 

These instructions contain information about safe handling of 
KYOCERA solar modules of the KK-series.  
They  are  directed  at  personnel  with  electro-technical  qualifi-
cations  and  contain  safety-relevant  instructions  for  the  as-
sembly, connection and maintenance of the solar modules.  

IMPORTANT 

The  solar  modules  may  only  be  mounted  by  personnel  with 
electro-technical qualifications. Appropriately qualified techni-
cians must always be deployed to service the units or remedy 
faults during operation. 
 
Please  read  these  instructions  carefully  before  handling  the 
solar  module  and  familiarise  yourself  with  the  safety  infor-
mation. After the module has been installed, hand over these 
instructions to the operator of the solar modules for safekeep-
ing. 

Description of the solar modules 

2.1 

Proper use 

The solar modules use the photovoltaic principle to turn light 
into  electricity.  The  solar  modules  are  primarily  designed  for 
connection  to  an  inverter  to  feed  the  energy  into  the  public 
power  grid.  When  connecting  to  a  charge  controller,  please 
observe  the  instructions  of  the  manufacturer  of  the  charge 
controller  and  accumulator.  Several  solar  modules  can  be 
connected in series or in parallel. 
The solar modules may not be directly connected to electrical 
consumers. 

2.2 

Description 

The  solar  modules  have  an  aluminium  assembly  frame  with 
assembly  and  grounding  holes.  The  solar  modules  have  a 
junction  box  and  solar  cables  with  plugs  for  the  electrical 
connection. 

Appendix  1

  of  these  instructions  contains  an 

illustration of a solar module. 

 

 

Designation 

 

Grounding holes 

 

Junction box 

 

Assembly holes 

 

Module frame 

 

Solar cable 

 

The  solar  modules  are  equipped  with  bypass  diodes.  In  the 
event  of  clouding,  these  minimise  the  losses  and  help  to 
prevent damage to the solar modules. The solar modules are 
not  equipped  with  blocking  diodes  preventing  battery  dis-
charging  at  night.  Most  PV  charge  regulators  incorporate 
nighttime disconnect  feature. The  solar modules  comply  with 
the application class A in accordance with IEC 61730-1. 

2.3 

Technical data 

Type designation

 

KK255P-3CB2CG 

Electrical data 

(at standard test conditions: Irradiation 1000 W/m

2

; air mass AM 1.5; module temperature 25°C)

 

P

max 

[W]

 

255 

V

oc

 [V] 

37.6 

I

SC

 [A] 

9.09 

V

pm

 [V] 

30.4 

I

pm

 [A] 

8.39 

Bypass diode (pre-installed) 

Number 

Temperature properties: Temperature coefficient 

V

oc

 [V/°C] 

-1.34*10

-1

 

I

sc

 [A/°C] 

5.33*10

-3

 

P

max

 [W/°C] 

-1.16 

Physical properties: 

Length [mm] 

1662 

Width [mm] 

990 

Height [mm] 

46 

Weight [kg] 

20.0 

Assembly holes 

Diameter 9 mm , 4 units 

Grounding holes 

Diameter 7 mm, 4 units 

Application class 

Class A 

Fire class 

Class C 

Series fuse rating [A] 

15 

 
ENG 

 

Summary of Contents for KK255P-3CB2CG

Page 1: ...a charge controller please observe the instructions of the manufacturer of the charge controller and accumulator Several solar modules can be connected in series or in parallel The solar modules may not be directly connected to electrical consumers 2 2 Description The solar modules have an aluminium assembly frame with assembly and grounding holes The solar modules have a junction box and solar ca...

Page 2: ...ing Risk of falling when working on roofs Use suitable fall protection equipment Do not perform assembly work in strong winds Only perform assembly work in dry weather conditions Observe the accident prevention regulations 4 2 Select the location NOTE Before installing the PV system contact local authorities to determine the necessary permits installation and inspection requirements During assembl...

Page 3: ... least 4 units Please observe the information provided by the manufacturer when selecting the clamps Installation with long side of frame must be at least 24mm long respectively must overlap the module frame by at least 5mm NOTE The module clamps or insertion system must not bend the module frame must not touch the front glass must not cast a shadow on the front glass must not damage the surface o...

Page 4: ... slope is adequate 15 degrees the solar mod ules do not need to be cleaned thanks to the self cleaning effect of the rain If heavily soiled clean with plenty of water a mild detergent and a soft cloth sponge 6 3 Solar module maintenance The system should be inspected once a year with regard to the following Secure hold and no rust on any of the attachments Secure connection cleanliness and that al...

Page 5: ... 1100mm 100mm 100mm 100mm 100mm 281mm 100mm 100mm 100mm 100mm 1100mm 100mm 100mm 100mm 100mm 281mm 100mm 100mm 100mm 100mm 1100mm 281mm 1100mm 281mm 1100mm 281mm 1100mm 281mm 1100mm 281mm 1100mm 281mm 1100mm 281mm 1100mm 281mm 100mm 100mm 1100mm 281mm 100mm 100mm 100mm 1100mm 281mm 100mm 200mm 100mm 100mm 1100mm 281mm 100mm 100mm 100mm 1100mm 281mm 100mm 200mm Permissible clamping range Zulässiger...

Reviews: