Ins
taller menu
Tank set point temperature
Anti-freezing
Weekly schedule active
Weekly schedule
Circulation pump
Language
Service menu
The controller controls the operation of the compressor, ventilator, integrated circulation pump, additional circulation
pump and electrical heater. The compressor is activated with a delay in relation to the circulation pump and ventilator -
compressor
delay
parameter.
The electrical heater operates above the
ECO-PLUS
temperature and in the event of a breakdown.
For the protection of the device against unwanted changes in settings e.g. by children, you can activate the lock - to
operate the
controller you must enter the access code.
After selecting the option of
Active Protection
the controller after a specified period of inactivity (
setting
Lock Delay
)
locks access to the menu functions of the controller. To unlock the driver must enter the four digit code which can be
defined in the
PIN Code Change
option.
The option allows you to set the current time.
The option allows you to set the current date.
The function allows you to define the brightness of the display during the edit and view of the controller functions in the
range
of 10-100%.
The function allows you to define the brightness of the display during the dimming, which is activated in 30 seconds
after the
end of the edit and view of the controller functions in the range of 5-100%.
The function allows you to preview the controller information - name of the manufacturer, software number, and service
telephone number.
This function is used to set the tank set-point temperature. The ventilator, the compressor and the pump work until the
tank setpoint
temperature is reached.
With this function the user specifies anti-freezing operations, which serve to protect the installation against freezing.
When the
temperature drops below a certain temperature threshold (factory set limit is 5
°
C) the heat pump or the heater
engages
permanently
;
it disengages when the temperature in the circuit reaches a value of temperature threshold
4.1
Control of actuators
4.2
Security
4.3
Clock settings
4.4
Date settings
4.5
Screen brightness
4.5.1
Screen brightness
4.5.2
Screen brightness
4.6
Programme information
5.1
Tank set point temperature
5.2
Anti-freezing
5
Installer menu
-8-