Please carefully check the modules of the existence of visual defects, focusing on the following items:
a)
Check whether the module glass is broken.
b)
Check if the front of the module is obstructed by obstacles or foreign objects.
c)
Check the module negative-sheet whether there is hot, negative film raised, burn through the traces
and so on.
d)
Check whether the cell bus–bar is corroded, whether encapsulation materials of the module has
delamination, bubbles, etc.
e)
Check the tightness of the bolts and the electrical connections at the connection points between the
modules and the supporting rail.
8.3 Inspection of connector and cable
It is advisable to carry out a preventive check every 6 months and check the following:
a)
Check Junction box adhesive for cracks or cracks.
b)
Check the connector interface sealing and whether there is loose, melt deformation, aging or corrode.
c)
Check that the cable connections are secure and that the modules are properly grounded.
When module is found to be defective, consult a qualified service technician. If servicing is required, it
should be serviced by a qualified service technician. Module exposure generates high voltages in the sun, so
cover the modules with opaque material when servicing modules to prevent electrical shock.
Note:
1.
if found in the maintenance of any problems, feed negative to the professional service personnel for confirmation;
2.
If using maintenance and repair measures not included in this manual, consult your local dealer for professional support.
9 Disclaimer of liability
9.1
Because the use of the manual and the conditions or methods of installation, operation, use and
maintenance of photovoltaic (PV) product are beyond Sunerg’s control, Sunerg does not accept responsibility
and expressly disclaims liability for loss, damage, or expense arising out of or in any way connected with such
installation, operation, use or maintenance.
9.2
Sunerg shall not be liable for damage to the product resulting from the installation or the design of the
power generation system.
9.3
No responsibility is assumed by Sunerg for any infringement of patents or other rights of third parties,
which may result from use of the PV product, No license is granted by implication or otherwise under any
patent or patent rights.
9.4
In the installation of modules, the customer is not in accordance with the requirements of the listed this
manual operation, Sunerg does not provide any warranty.
9.5
The information in this manual is based on Sunerg’s knowledge and experience and is believed to be
reliable, but such information including product specification (without limitations) and suggestions do not
constitute a warranty, expresses or implied.
9.6
Sunerg reserve the right to change the manual, module technical specification, nameplate or product
information sheets without prior notice.