background image

 5

 Tips before installation

Your Room Air Conditioner unit is designed to 
be highly  efficient and save energy. Follow these
recommendations for greater efficiency.

1. Select thermostat setting that suits your 
comfort needs and leave the thermostat at 
that chosen setting.

2. The air filter is very efficient in removing airborne
particles. Keep the air filter clean. Typically, the  filter
should be cleaned once a month. More
frequent cleaning may be necessary depending 
on outdoor and indoor air quality.

3.  Use drapes, curtains, or shades to keep
direct sunlight from heating your room, but 
DO NOT obstruct the air conditioner. Allow air to 
circulate around the unit without obstructions.

4. Start your air conditioner before outdoor 
air becomes hot/cold and uncomfortable. This 
avoids an initial period of discomfort while 
the unit is cooling or heating off the room.

5. When outdoor temperature is cool 
enough, use

 HIGH 

or 

LOW FAN

 

only. This circulates indoor air, providing
some cooling comfort, and utilizes less 
electricity than when operating on a 
cooling setting.

To avoid installation/operating difficulties,
read the instructions thoroughly.

NOTE:

      Save the shipping carton and packing 

materials for future storage or transport of the unit. 
Please check the contents of the hardware kit against 
the corresponding model check list, prior to 
installation of the unit.

See lists below.(Fig.A)

CAUTION

!

!

Your Room Air Conditioner was designed 
for easy installation in a single or double-hung 
window. 

NOTE:

 This unit is 

NOT

 designed for 

vertical (slider type) windows. 

Tools Needed for Window Installation
Screw  drivers:    Both  Philips  and  flat  head
Power  drill:         1/8 inch  diameter  drill  bit
Pencil
Measuring tape
Scissors
Carpenters level

3/4

Screws (10)

Top Channel(1)

End Cap &
Leveling Legs(2)

Lock Washers(4)

Mounting
Brackets(2)
Angle
Brackets(2)

1-1/2

x1/4 Bolts(4)

Side Curtain RH(1)
Side Curtain LH(1)

Shutter Clamp(2)

Fig. 1A Installation Hardware Model 463AAC008BA 

1/4

Screws (23)

Top Channel(1)

Seal(1)

Lock Washers(4)

1/4

Nuts(4)

Mounting
Brackets(2)
Angle
Brackets(2)

Side Curtain RH(1)
Side Curtain LH(1)

Shutter Clamp(2)

 Fig. A  Installation Hardware

Gasket(10)

NOTE: Surplus screw(s) for spare use.

Foam (1)

Double 
Adhering 
Seal(1)

Bottom Channel(1)
(F

or 15K to 24K models

)

(Factory-installed)

Bottom Channel(1)
(

For 8K to 12K models

)

Summary of Contents for SAW24CR3FHUE

Page 1: ...User s Manual 24 000 BTU Room Air Conditioner SAW24CR3FHUE PTT042106...

Page 2: ...Contents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide Page 2 2 4 5 6...

Page 3: ...before starting This manual contains information for the installation and operation of your room air conditioner Note The figures in this manual are based on the external view of a standard model Cons...

Page 4: ...the air conditioner you have selected Introduction Control Panel Part Identification Remote control model Cabinet Exterior Air Inlet Air Outlet Fresh Air Vent Lever Control Panel Power Cord Front Pane...

Page 5: ...to use the correct power supply according to the rating plate of your air conditioner 125 8K 15K 22K 24K Table 1 15 15 If the air conditioner has a serial plate rating of 115 volts and up to and incl...

Page 6: ...ling setting To avoid installation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check...

Page 7: ...designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe and proper installation B Make sure window and fra...

Page 8: ...er 1 4 screw For 8K to 12K models Channel 1 4 Screw Fig 3 Fig 4 Installation instructions 3 Assembly of the upper lower channels to the cabinet A L Shaped Top Channel Stick the double adhering seal to...

Page 9: ...3 4 screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3 16 Maximum B Measure the inside window sill width and find the center as shown in Fig 6 Align the V slot in each brack...

Page 10: ...Shutters A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the ca...

Page 11: ...moval may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations...

Page 12: ...air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL NOTE After setting t...

Page 13: ...e below 32 the Temperature display L0 Room Temperature above 99 the Temperature display H1 NOTE Temperature setting range is from 19 66 to 31 88 Fan Speed button Used to select fan speed in sequence a...

Page 14: ...ct the Auto mode fan speed 9 Saver BUTTON Used to select the mode Energy saving The Above symbols are shown when the relevant mode is in use High fan speed Medium fan speed Low fan speed Auto fan spee...

Page 15: ...ignal receptor of indoor unit The remote control is NOT preset as Cooling only or Heat Pump by manufacturer Each time after the remote control replaces batteries or is energized the Cooling indicator...

Page 16: ...front grille To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure DO NOT forget to install the air filter If the air cond...

Page 17: ...ngle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Add flexible tubi...

Page 18: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Reviews: