background image

 11

When using FAN control, turn slowly allowing
unit to adjust.

When using 

THERMOSTAT

, be sure to allow

three minutes before changing temperature. 
Adjusting too quickly may cause an overload
resulting in a blown fuse.

CAUTION

!

!

MODE

The mode knob controls fan speeds and cooling
speeds. To set desired cooling temperature, simply
rotate the mode knob dial to the appropriate
setting.

LOW FAN

 will circulate the air at a minimum speed

without cooling.

MED FAN

 will circulate the air at a middle speed

without cooling.

HIGH FAN

 will circulate the air at a maximum speed

without cooling.

LOW COOL

 provides cooling, automatically with

minimum air circulation. Recommended for night-
time use.

MED COOL

 provides cooling, automatically with

middle air circulation. Recommended for night-
time use.

HIGH COOL

 provides cooling, automatically with

quick cooling or for extremely hot days. Once room 
is cooled, reduce setting to

 LOW COOL

.

NOTE:

 After setting the mode, allow 3 

minutes before switching to another mode. 

OFF 

will completely shut-off the unit.

THERMOSTAT

The thermostat automatically controls the cooling 
cycle (compressor) of the air conditioner to maintain
room temperature. However, the fan motor will
continue to operate after the compressor (cooling
cycle) is completed. 

Fresh Air Ventilation

 is usually kept in the closed

position. Use only when clearing smoke and/or
odors from the room. Pull to open.

Operating Instructions

Fig. 15

Mechanical control model

Thermostat
knob

Mode knob

Fig. 16

Fresh Air 
Vent Lever

F
HR

  FAN
SPEED

MODE

OFF

ON

/

TIMER

Airconditioner

WAIT THREE MINUTES 

BEFORE RESTARTING

LOW
FAN

MED
FAN

HIGH
FAN

OFF

HIGH
COOL

MED
COOL

LOW
COOL

1

3

5

7

9

C

O

L

E

R

O

1

3

Summary of Contents for SAW24CR3FHUE

Page 1: ...User s Manual 24 000 BTU Room Air Conditioner SAW24CR3FHUE PTT042106...

Page 2: ...Contents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide Page 2 2 4 5 6...

Page 3: ...before starting This manual contains information for the installation and operation of your room air conditioner Note The figures in this manual are based on the external view of a standard model Cons...

Page 4: ...the air conditioner you have selected Introduction Control Panel Part Identification Remote control model Cabinet Exterior Air Inlet Air Outlet Fresh Air Vent Lever Control Panel Power Cord Front Pane...

Page 5: ...to use the correct power supply according to the rating plate of your air conditioner 125 8K 15K 22K 24K Table 1 15 15 If the air conditioner has a serial plate rating of 115 volts and up to and incl...

Page 6: ...ling setting To avoid installation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check...

Page 7: ...designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe and proper installation B Make sure window and fra...

Page 8: ...er 1 4 screw For 8K to 12K models Channel 1 4 Screw Fig 3 Fig 4 Installation instructions 3 Assembly of the upper lower channels to the cabinet A L Shaped Top Channel Stick the double adhering seal to...

Page 9: ...3 4 screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3 16 Maximum B Measure the inside window sill width and find the center as shown in Fig 6 Align the V slot in each brack...

Page 10: ...Shutters A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the ca...

Page 11: ...moval may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations...

Page 12: ...air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL NOTE After setting t...

Page 13: ...e below 32 the Temperature display L0 Room Temperature above 99 the Temperature display H1 NOTE Temperature setting range is from 19 66 to 31 88 Fan Speed button Used to select fan speed in sequence a...

Page 14: ...ct the Auto mode fan speed 9 Saver BUTTON Used to select the mode Energy saving The Above symbols are shown when the relevant mode is in use High fan speed Medium fan speed Low fan speed Auto fan spee...

Page 15: ...ignal receptor of indoor unit The remote control is NOT preset as Cooling only or Heat Pump by manufacturer Each time after the remote control replaces batteries or is energized the Cooling indicator...

Page 16: ...front grille To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure DO NOT forget to install the air filter If the air cond...

Page 17: ...ngle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Add flexible tubi...

Page 18: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Reviews: