1. All wiring must comply with local and national
electrical codes and must be installed by a 
licensed electrician.  If you have any questions
regarding the following instructions, contact a 
licensed electrician.

2. Check available power supply and resolve any
wiring problems 

BEFORE

 installing and operating 

this unit.

3. For your safety and protection, this unit is
grounded through the power cord  when
plugged into a matching wall outlet.  

If you are

not sure whether your wall outlet is properly
grounded, please consult a licensed 
electrician

.

4. The wall outlet (3-pin) must match the plug
(3-pin) on the power cord supplied with the unit.
DO NOT use plug adapters or extension cords.

See (Table 1)

 for receptacle and fuse information. 

5. The rating plate on the unit contains electrical 
and other technical data.  The rating plate is 
located on the right side of the unit.  Make sure 
to use the correct power supply according to the 
rating plate of your air conditioner.

125

8K-15K

22K-24K

Table 1

15

15

If the air conditioner has a serial plate rating
of 115 volts and up to and including 7.5 amps,
the unit maybe on a fuse or circuit breaker
with other devices.  However, the maximum 
amps on all devices for  that fuse or circuit 
breaker can not exceed the amps of the fuse
for the circuit breaker.

If the air conditioner has a serial plate rating
of 115 volts and greater than 7.5 amps it 
must have its own fuse or circuit breaker, 
and no other device or unit should be 
operated on the fuse or circuit breaker.

If the air conditioner has a serial plate rating
of 230 volts,  it must have its own fuse or 
circuit breaker, and no other device or unit
should be operated on the fuse or circuit 
breaker.

To avoid the possibility of personal injury, 
disconnect power to the unit before installing
or servicing.

Electric Shock Hazard

Electrical specifications

RATED VOLTS

COOLING CAPACITY

250

AMPS

FUSE SIZE

WALL OUTLET

20

20

             RECEPTACLE AND FUSE TYPES

!

18K

250

15

15

Summary of Contents for SAW24CR3FHUE

Page 1: ...User s Manual 24 000 BTU Room Air Conditioner SAW24CR3FHUE PTT042106...

Page 2: ...Contents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide Page 2 2 4 5 6...

Page 3: ...before starting This manual contains information for the installation and operation of your room air conditioner Note The figures in this manual are based on the external view of a standard model Cons...

Page 4: ...the air conditioner you have selected Introduction Control Panel Part Identification Remote control model Cabinet Exterior Air Inlet Air Outlet Fresh Air Vent Lever Control Panel Power Cord Front Pane...

Page 5: ...to use the correct power supply according to the rating plate of your air conditioner 125 8K 15K 22K 24K Table 1 15 15 If the air conditioner has a serial plate rating of 115 volts and up to and incl...

Page 6: ...ling setting To avoid installation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check...

Page 7: ...designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe and proper installation B Make sure window and fra...

Page 8: ...er 1 4 screw For 8K to 12K models Channel 1 4 Screw Fig 3 Fig 4 Installation instructions 3 Assembly of the upper lower channels to the cabinet A L Shaped Top Channel Stick the double adhering seal to...

Page 9: ...3 4 screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3 16 Maximum B Measure the inside window sill width and find the center as shown in Fig 6 Align the V slot in each brack...

Page 10: ...Shutters A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the ca...

Page 11: ...moval may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations...

Page 12: ...air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL NOTE After setting t...

Page 13: ...e below 32 the Temperature display L0 Room Temperature above 99 the Temperature display H1 NOTE Temperature setting range is from 19 66 to 31 88 Fan Speed button Used to select fan speed in sequence a...

Page 14: ...ct the Auto mode fan speed 9 Saver BUTTON Used to select the mode Energy saving The Above symbols are shown when the relevant mode is in use High fan speed Medium fan speed Low fan speed Auto fan spee...

Page 15: ...ignal receptor of indoor unit The remote control is NOT preset as Cooling only or Heat Pump by manufacturer Each time after the remote control replaces batteries or is energized the Cooling indicator...

Page 16: ...front grille To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure DO NOT forget to install the air filter If the air cond...

Page 17: ...ngle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Add flexible tubi...

Page 18: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Reviews: