14

How to Insert the Batteries

Remove the battery cover according to the arrow direction. 

Insert new batteries making sure that the (+) and (-) of
battery are matched correctly.

Reattach the cover by sliding it back into position.

Note:

Use 2 LR03 AAA (1.5volt) batteries. Do not use rechargeable batteries.
Replace batteries with new ones of the same type when the display 
becomes dim.

 Remote control

If the replacement is done within 1 minute, the remote control
will keep original presetting. 

Operating Instructions

How to Use

To  operate  the  room air conditioner , aim 
the remote control to the signal receptor.
The  remote control  will operate  the air 
conditioner at  a  distance  of up to 23 feet
when pointing at signal receptor of  indoor 
unit.

The remote control is NOT preset as Cooling   

only or Heat Pump by manufacturer.

 

Each time after the remote control replaces batteries 

or is energized, the Cooling indicator and Heating   

indicator

will flashes alternately on LCD of the remote control.

 

User can preset the remote control type depending   

on the air conditioner type you have purchased as follows:

 

Press any button when

 

flashes, Heat Pump will be set. 

Press any button when

 

flashes, Cooling Only will be set. 

If you don not press any button within 12 seconds, the remote control will be set as Heat Pump 

automatically. 

Back-light function(optional)

 

Remote Control Presetting

 

Hold down any button of rem ote control for about 2 seconds, back-light turns on. Release the 

button, it lights off automatically 10 seconds later.

 

Signal receptor

F
HR

  FAN
SPEED

MODE

OFF

ON

/

TIMER

Airconditioner

WAIT THREE MINUTES 

BEFORE RESTARTING

Summary of Contents for SAW24CR3FHUE

Page 1: ...User s Manual 24 000 BTU Room Air Conditioner SAW24CR3FHUE PTT042106...

Page 2: ...Contents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide Page 2 2 4 5 6...

Page 3: ...before starting This manual contains information for the installation and operation of your room air conditioner Note The figures in this manual are based on the external view of a standard model Cons...

Page 4: ...the air conditioner you have selected Introduction Control Panel Part Identification Remote control model Cabinet Exterior Air Inlet Air Outlet Fresh Air Vent Lever Control Panel Power Cord Front Pane...

Page 5: ...to use the correct power supply according to the rating plate of your air conditioner 125 8K 15K 22K 24K Table 1 15 15 If the air conditioner has a serial plate rating of 115 volts and up to and incl...

Page 6: ...ling setting To avoid installation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check...

Page 7: ...designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe and proper installation B Make sure window and fra...

Page 8: ...er 1 4 screw For 8K to 12K models Channel 1 4 Screw Fig 3 Fig 4 Installation instructions 3 Assembly of the upper lower channels to the cabinet A L Shaped Top Channel Stick the double adhering seal to...

Page 9: ...3 4 screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3 16 Maximum B Measure the inside window sill width and find the center as shown in Fig 6 Align the V slot in each brack...

Page 10: ...Shutters A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the ca...

Page 11: ...moval may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations...

Page 12: ...air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL NOTE After setting t...

Page 13: ...e below 32 the Temperature display L0 Room Temperature above 99 the Temperature display H1 NOTE Temperature setting range is from 19 66 to 31 88 Fan Speed button Used to select fan speed in sequence a...

Page 14: ...ct the Auto mode fan speed 9 Saver BUTTON Used to select the mode Energy saving The Above symbols are shown when the relevant mode is in use High fan speed Medium fan speed Low fan speed Auto fan spee...

Page 15: ...ignal receptor of indoor unit The remote control is NOT preset as Cooling only or Heat Pump by manufacturer Each time after the remote control replaces batteries or is energized the Cooling indicator...

Page 16: ...front grille To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure DO NOT forget to install the air filter If the air cond...

Page 17: ...ngle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Add flexible tubi...

Page 18: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Reviews: