74
Sun Dual Gigabit Ethernet and Dual SCSI/P Adapter Installation and User’s Guide • January 2004
4. Set the
diag-switch?
parameter to true in order to see the diagnostic power-on
self-test (POST) messages.
5. Reset the system to activate these parameter changes.
6. Use the
show-nets
command to display the list of network devices on the
system.
Among the list of devices, you should see the two interfaces specific to the Sun Dual
Gigabit Ethernet and Dual SCSI/P adapter you want to test, as shown in the
following example.
Note –
The preceding device paths are examples. The actual device paths on your
system may be different from the examples shown here.
7. Use the
test
command, and the device paths found in Step 6, to test the adapter
when you use the FCode self-test.
Refer to the appropriate OpenBoot Command Reference Manual for more information
on the
test
command.
The following tests are run when you execute the
test
command:
■
MAC internal loopback
■
1000 Mbps PHY loopback
■
100 Mbps PHY loopback
■
10 Mbps PHY loopback
ok setenv diag-switch? true
ok reset-all
ok show-nets
a) /pci@1f,700000/network@2
b) /pci@1e,600000/pci@4/network@1
c) /pci@1e,600000/pci@4/network@0
q) NO SELECTION
Enter Selection, q to quit:
ok test
device_path