background image

Mitsubishi Electric Programmable Controller
Upgrade Tool

Base Adapter

Model

ERNT-AQB35N
ERNT-AQB38N
ERNT-AQB55N
ERNT-AQB58N
ERNT-AQB65N
ERNT-AQB68N

User’s Manual

50CM-D180346-B(1806)

HEAD OFFICE: Hulic KUDAN BLDG.1-13-5

KUDANKITA CHIYODA-KU

TOKYO 102-0073

JAPAN

NAGOYA ENGINEERING OFFICE:139 SHIMOYASHIKICHO-SHIMOYASHIKI

KASUGAI

AICHI 486-0906

JAPAN

SAFETY PRECAUTIONS

(Always read these precautions prior to use.)

Before using this product, please read this manual carefully and pay full attention to safety
to ensure that the product is used correctly.
The precautions presented in this manual are concerned with this product only. For
Programmable Controller system safety precautions, refer to the following manuals.

MELSEC-Q series: QCPU User’s Manual (SH-080483ENG)

MELSEC iQ-R series: Safety Guidelines (IB-0800525E)

In this manual, the safety precautions are ranked as “WARNING” and “CAUTION.”

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

WARNING

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or minor injury and/or
property damage.

CAUTION

Note that failure to observe the

CAUTION level instructions may lead to a serious

consequence according to the circumstances. Always follow the precautions of both levels
because they are important to personal safety.
Please keep this manual in an easy-to-access location for future reference, and be sure to
provide the manual to the end user.

[

Installation Precautions

]

WARNING

Be sure to shut off all phases of the external power supply before performing
installation work. Failure to do so could result in electric shock or product
damage.

CAUTION

Use the base adapter in the environmental conditions that are specified in the
general specification in the following manuals. Failure to do so could lead to
electric shock, fire, malfunction or product failure or deterioration.

MELSEC-Q series: QCPU User’s Manual (SH-080483ENG)

MELSEC iQ-R series: Safety Guidelines (IB-0800525E)

Fully secure the base adapter, Programmable Controller base unit (MELSEC-Q
Series, MELSEC iQ-R Series), and conversion adapter anchor base using the
installation screws, and securely tighten the screws within the specified torque
range. Failure to do so could cause the product to fall, resulting in damage.

[

Startup and Maintenance Precautions

]

WARNING

Be sure to shut off all phases of the external power supply before cleaning and
retightening the installation screws. Failure to do so could lead to electric shock.
Excessively tightened screws could result in damage, causing the product to fall,
a short circuit or product malfunction.

[Disposal Precautions]

CAUTION

When disposing of the product, treat it as industrial waste.

● 安全注意事项 ●

(

使用前请务必阅读

)

使用本产品时,请仔细阅读本手册,并充分注意安全,正确地使用产品。
本手册中标注的注意事项仅记载了与本产品相关的内容。关于可编程控制器系统的安全
注意事项

,

请参照下面的说明手册。

MELSEC-Q series: QCPU User’s Manual (SH-080483ENG)

MELSEC iQ-R series: Safety Guidelines (IB-0800525E)

在本●安全注意事项●中,安全注意事项的等级分为「警告」和「注意」。

警告

表示错误操作可能造成危险后果,引起死亡或重伤事故。

注意

表示错误操作可能造成危险后果,引起中度伤害,轻伤及财
产损失。

另外,根据情况不同,即使是

注意中记载的事项,也可能引发严重后果。不管哪个

记载的都是非常重要的内容,请务必遵守。
请妥善保管本手册,以便需要时取阅,并请将本手册交给最终用户。

【安装注意事项】

警 告

必须将外部供应电源全相断开后再进行安装作业等。如果未全相断开,可能会导致

触电或产品损坏。

注 意

基板适配器被要求在下面手册里所记载的一般规格环境下使用。如果在一般规格范

围以外的环境中使用,可能导致触电、火灾、误动作、产品的损坏或劣化。

基板适配器及所使用的可编程控制器模块基板

(

MELSEC-Q

系列

MELSEC iQ-R

)

应通过安装螺钉切实加以固定,安装螺钉应在规定的扭矩范围内切实地拧紧。

可能因掉落而导致破损。

【启动和维护注意事项】

警 告

在清扫或重新紧固端子螺栓时,必须将外部供应全相断开后再进行。如果未全相断

开,可能会导致触电。如果螺栓拧得过紧,可能会导致掉落、短路或误动作。

【废弃注意事项】

注 意

废弃时请将本产品作为工业废弃物处理。

EMC AND LOW VOLTAGE DIRECTIVES

Compliance to the EMC Directive, which is one of the EU Directives, has been a
legal obligation for the products sold in European countries since 1996 as well as
the Low Voltage Directive since 1997.
Manufacturers who recognize their products are compliant to the EMC and Low
Voltage Directives are required to declare that print a "CE mark" on their products.

Authorized representative in Europe

Authorized representative in Europe is shown below.
Name: Mitsubishi Electric Europe B.V.
Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany

1

Overview

This manual describes the Mitsubishi Electric Programmable Controller Upgrade Tool
base adapter (ERNT-AQB38N, ERNT-AQB35N, ERNT-AQB58N, ERNT-AQB55N,
ERNT-AQB68N, ERNT-AQB65N). The base adapter is a product that enables
MELSEC-Q series (hereinafter called Q Series) or MELSEC iQ-R series (hereinafter
called iQ-R Series) installation using the MELSEC-A series (hereinafter called A
Series) installation holes. (Additional hole machining not required)
Once you have opened the packaging, verify that it contains the following products.

Product

Shape

Quantity

Base adapter

1

Base unit installation screws (M4 x 8)

4

This manual

1

2

Product Specifications

(1) A Series

Q Series

Base Adapter

Model

Specifications

A Series

Compatible Module

Q Series

Compatible Module

Installable

Conversion Adapter

Anchor Base

Weight

(g)

ERNT-

AQB38N

A38B

A38B-UL

A38B-E

A38HB

A38HBEU

Q312B

Q38B

ERNT-AQF12

ERNT-AQF8

970

ERNT-

AQB68N

A68B

A68B-UL

Q612B

Q68B

930

ERNT-

AQB58N

A58B

A58B-UL

Q68B(*1)

ERNT-AQF8

870

ERNT-

AQB35N

A35B

A35B-UL

A35B-E

Q38B
Q35B

ERNT-AQF8
ERNT-AQF5

795

ERNT-

AQB65N

A65B

A65B-UL

Q68B
Q65B
Q55B

790

ERNT-

AQB55N

A55B

A55B-UL

Q65B(*1)

Q55B

ERNT-AQF5

655

*1

Base unit that requires installation of a power supply module.

(2) A Series

iQ-R Series

Base Adapter

Model

Specifications

A Series

Compatible Module

iQ-R Series

Compatible Module

Installable

Conversion Adapter

Anchor Base

Weight

(g)

ERNT-

AQB38N

A38B

A38B-UL

A38B-E

A38HB

A38HBEU

R312B

ERNT-1AR12F

970

R38B

ERNT-1AR8F

ERNT-

AQB68N

A68B

A68B-UL

R612B

ERNT-1AR12F

930

R68B

ERNT-1AR8F

ERNT-

AQB58N

A58B

A58B-UL

R68B(*1)

ERNT-1AR8F

870

ERNT-

AQB35N

A35B

A35B-UL

A35B-E

R38B

ERNT-1AR8F

795

R35B

ERNT-1AR5F

ERNT-

AQB65N

A65B

A65B-UL

R68B

ERNT-1AR8F

790

R65B

ERNT-1AR5F

ERNT-

AQB55N

A55B

A55B-UL

R65B (*1)

ERNT-1AR5F

655

*1

Base unit that requires installation of a power supply module.

3

Mounting and Installation

3.1 Handling Precautions

(1) Do not drop or apply heavy impact to the base adapter. Doing so could result in

damage.

(2) Fully secure the Q Series or iQ-R Series base unit and conversion adapter

anchor base using the installation screws, and securely tighten the screws
within the specified torque range. Loose screws could cause a short circuit, fire
or malfunction.

Screw Location

Tightening Torque Range

Base unit installation screw (M4 screw)

1.39to1.89N

m

Conversion adapter anchor base installation screw (M4 screw)

3.2 Installation Environment

Refer to the manual supplied with the Q Series or iQ-R Series module you use.

Q series: QCPU User’s Manual (SH-080483ENG)

iQ-R series: Safety Guidelines (IB-0800525E)

4

Installation Dimensions

(1) The width dimension is smaller than that of the A series.
(2) The base adapter installation holes (4 locations) have the same installation

dimensions as those of the A series base unit. There is no need for additional screw
hole machining on the control panel.

<Q Series or iQ-R Series>

<(Reference) A Series>

2

40

2

00

A

B

(C)

C

25

(1

5)

CPU

POWER

2

50

2

00

A

B

(C)

C

2

5

(2

5)

I/O

I/O

I/O

I/O

I/O

I/O

I/O

I/O

CPU

POWER

Base Adapter Model

A

B

C

A Series

Base Unit Model

A

B

C

ERNT-AQB38N

480

460

10

A38B(-UL/-E)

A38HB(EU)

480

460

10

ERNT-AQB68N

466

446

10

A68B(-UL)

466

446

10

ERNT-AQB58N

411

391

10

A58B(-UL)

411

391

10

ERNT-AQB35N

382

362

10

A35B(-UL/-E)

382

362

10

ERNT-AQB65N

352

332

10

A65B(-UL)

352

332

10

ERNT-AQB55N

297

277

10

A55B(-UL)

297

277

10

5

Q Base Unit and Conversion Adapter Anchor Base
Installation Locations

5.1 ERNT-AQB38N

c

d

Conversion Adapter

Anchor Base

Base Unit

Q Series

iQ-R Series

ERNT-AQF12

ERNT-AQF8

ERNT-1AR12F

ERNT-1AR8F

Q Series

Q312B

A

A

Combination

not possible

Combination

not possible

a

a

Q38B

Combination

not possible

B

Combination

not possible

Combination

not possible

b

iQ-R Series

R312B

Combination

not possible

Combination

not possible

A

Combination

not possible

c

R38B

Combination

not possible

Combination

not possible

Combination

not possible

B
d

Upper half

Base unit installation location

Lower half

Conversion adapter anchor base screw tightening location

5.2 ERNT-AQB68N

c

d

Conversion Adapter

Anchor Base

Base Unit

Q Series

iQ-R Series

ERNT-AQF12

ERNT-AQF8

ERNT-1AR12F

ERNT-1AR8F

Q Series

Q612B

A

A

Combination

not possible

Combination

not possible

a

a

Q68B

Combination

not possible

B

Combination

not possible

Combination

not possible

b

iQ-R Series

R612B

Combination

not possible

Combination

not possible

A

Combination

not possible

c

R68B

Combination

not possible

Combination

not possible

Combination

not possible

B

d

Upper half

Base unit installation location

Lower half

Conversion adapter anchor base screw tightening location

Reviews: