3-4
SPARCserver 1000 System Service Manual—June 1996
3
Figure 3-3
Branch A.1: Control Board
A.2
Yes
B
Yes
Read POST error
messages.
Are DC LEDs OK
on control board?
No
Are status LEDs
OK on control
board?
No
Yes
Replace DC power supply if necessary.
No
No
Yes
A.2
A.1
Replace control board if necessary.
Can POST
diagnostics run?