Chapter 2
Hardware Installation and Service
2-15
■
A
telnet
utility (Connect to the proper port on a Network Terminal Server to
which the Sun Netra CP3250 blade server is connected.)
■
Another suitable serial communications program on the system console
For example, if you are using a UNIX system as the system console, at the UNIX
prompt in a command tool or shell tool, or serial port A, type:
2.2.4.2
Connecting Cables to the System Console Not Running the
Solaris OS
1. Connect a serial cable to the serial console port on the front panel of the Sun
Netra CP3250 blade server (
FIGURE 2-4
) or the Netra CP32x0 rear transition
module.
2. Connect the other end of the serial cable to the serial port of the system serving
as the system console.
3. Set the serial communications settings to 9600 baud, 8 bit, 1 stop bit, no parity,
and no handshake.
2.2.4.3
Netinstall Boot Device Map
TABLE 2-2
provides a map of netinstall boot devices. You may need this information
to understand which MAC address is associated with the system IP address on the install
server.
For example, the Base Fabric interface is connected to the switch model-number in
slot 8 of the ATCA shelf. To install to this device, select the xxx Ethernet interface
from the BIOS setup menus.
#
tip -9600 /dev/ttya
TABLE 2-2
Netinstall Boot Device Table
MAC Address
Solaris
Device
Hardware
Device
Connects to...
Switch Slot
Connection
00:14:4f:xx.yy.zz+0
bge0
(BMC5715C)
Base Fabric 0
Slot 7
00:14:4f:xx.yy.zz+1
bge1
(BMC5715C)
Base Fabric 1
Slot 8
00:14:4f:xx.yy.zz+2
bge2
(MCP55)and
(BCM5715C)
mgtA (front panel)
00:14:4f:xx.yy.zz+3
bge3
(MCP55)and
(BCM5715C)
mgtB (rear panel)
Summary of Contents for Sun Netra CP3250
Page 8: ...viii Sun Netra CP3250 Blade Server User s Guide April 2009...
Page 12: ...xii Sun Netra CP3250 Blade Server User s Guide April 2009...
Page 18: ...xviii Sun Netra CP3250 Blade Server User s Guide April 2009...
Page 34: ...1 16 Sun Netra CP3250 Blade Server User s Guide April 2009...
Page 70: ...2 36 Sun Netra CP3250 Blade Server User s Guide April 2009...
Page 72: ...3 2 Sun Netra CP3250 Blade Server User s Guide April 2009 3 1 Block Diagram...
Page 80: ...3 10 Sun Netra CP3250 Blade Server User s Guide April 2009...
Page 94: ...5 10 Sun Netra CP3250 Blade Server User s Guide April 2009...
Page 96: ...A 2 Sun Netra CP3250 Blade Server User s Guide April 2009 FIGURE A 1 BIOS Main Menu...
Page 97: ...Appendix A BIOS Screens A 3 FIGURE A 2 Advanced Configuration Menu...
Page 98: ...A 4 Sun Netra CP3250 Blade Server User s Guide April 2009 FIGURE A 3 CPU Configuration Menu...
Page 99: ...Appendix A BIOS Screens A 5 FIGURE A 4 IDE Configuration Menu...
Page 100: ...A 6 Sun Netra CP3250 Blade Server User s Guide April 2009 FIGURE A 5 USB Configuration Menu...
Page 101: ...Appendix A BIOS Screens A 7 FIGURE A 6 Event Log Control Menu...
Page 103: ...Appendix A BIOS Screens A 9 FIGURE A 8 Remote Access Configuration Menu...
Page 105: ...Appendix A BIOS Screens A 11 FIGURE A 10 Trusted Computing Menu...
Page 106: ...A 12 Sun Netra CP3250 Blade Server User s Guide April 2009 FIGURE A 11 Boot Settings Menu...
Page 107: ...Appendix A BIOS Screens A 13 FIGURE A 12 Boot Device Priority Configuration Menu...
Page 108: ...A 14 Sun Netra CP3250 Blade Server User s Guide April 2009 FIGURE A 13 Security Settings Menu...
Page 109: ...Appendix A BIOS Screens A 15 FIGURE A 14 Exit Menu...
Page 110: ...A 16 Sun Netra CP3250 Blade Server User s Guide April 2009...
Page 125: ...Appendix B Physical Characteristics B 15...
Page 126: ...B 16 Sun Netra CP3250 Blade Server User s Guide April 2009...