Chapter 2
Setting Up the System
43
Note –
When hot-swapping a power supply, do not disengage and reengage the
supply in rapid succession. Rapid seating and unseating of a power supply will
result in false error conditions. After removing a supply, wait for an
acknowledgement message on the system console before installing a new supply;
otherwise, the environmental monitoring software will not recognize the new device
and false error conditions will result.
6. If you removed a power supply from the left-hand bay and you are not replacing
it immediately, install a power supply filler panel into the empty bay.
Insert the power supply filler panel into the bay and tighten the two Phillips screws
that secure the filler panel to the back of the system.