24
NOTE: The heading will be either SEED / FERT / LEFT / RIGHT according to steps 2a , 2b.
5.
Press ENTER again for the instrument to re-calculate and display the new calibration factor in
kg/rev, the error %, and the maximum forward speed that is permissible based on the
application rate set for the product (Fig.20).
Figure 20. Calibration confirmation screen
6.
Press ENTER again to confirm and store the new calibration factor, or press ESC to return to
the SETUP menu screen.
It is recommended to reset the PART TOTAL to zero before commencing drilling. This will
enable you after drilling an area, to quantify any error in the calibration factor by logging the
theoretical amount of product used against a known amount used (a whole bag for example).
You can then adjust the calibration factor precisely, if necessary (section 2.7.2).
Figure 17. Pre-calibration
screen
Figure 18. During calibration
screen
Figure 19. Calibration correction screen