SummaSign Pro T-series Cutters
User’ s Manual
General Information
1-8
1.2.8. ENVIRONMENTAL
(cutter without media)
Operating Temperature
15 to 35
°
C
59 to 95
°
F
Storage temperature
-30 to 70
°
C
-22 to 158
°
F
Relative humidity
35 - 85 %, non con-
densing
35 - 85 %, non con-
densing
TABLE 1-7 :
SUMMASIGN PRO T-SERIES ENVIRONMENTAL SPECIFICATIONS
IMPORTANT HINT
The use of dimensionally stable media is an essential pre-requisite to
obtaining high cut quality. Additionally, media expansion or
contraction may occur as a result of temperature variations.
To improve the dimensional stability of media, let it stabilize to the
current environmental conditions before usage, for a minimum period
of 24 hours.
1.2.9. ELECTRICAL
Mains Supply : 48-62 Hz, single phase.
Nominal line
Min./Max. line
Fuse
100 V AC
89 - 108 V AC
1.25 A, Slo-Blo
120 V AC
108 - 130 V AC
1.25 A, Slo-Blo
220 V AC
197 - 238 V AC
0.6 A, Slo-Blo
240 V AC
216 - 260 V AC
0.6 A, Slo-Blo
TABLE 1-8 :
SUMMASIGN PRO T-SERIES ELECTRICAL SPECIFICATIONS
Summary of Contents for T1010 Pro
Page 1: ......