32
Stoppage
period
Approx. 1 month
More than 1 month
Change the oil and operate the unit for several minutes before stopping the unit.
Flush the unit, supply rust-preventive oil, and operate the unit without a load for several
minutes before stopping the unit.
• Always replace old oil with new oil when re-operating after long-term stoppage. The old oil may have
deteriorated.
8-4) Grease Supply and Replacement of
Grease Lubricated Input Side (CYCLO Part)
(1) Grease Refill and Replacement Timing
Model
Grease and Supply and Replacement Interval
Grease-lubricated
(Long-life type) models
( section in Table 8 on page 24)
These models are filled with long-life grease, BEN10-No.2.
This enables operation for extended periods without
supplying. However, oil replacement after every 20,000
hours or 3 to 5 years by disassembling the unit will ensure
longer lifetime.
Grease-lubricated models other
than long-life type
Refer to Tables 17 and 18 for supply and change of
grease.
Table 16 Timing of Supply and Replacement of Grease
(Other than Long-life types)
Hours of
operation
10 hr max./day
10 – 24 hr/day
Replenishment
interval
3 – 6 months
Remarks
Shorten the supply interval
when the operating
conditions are severe or the
frame size is large.
Change interval
Every 20,000 hrs or
3 – 5 years
Remarks
Shorten the supply interval
when the operating
conditions are severe or the
frame size is large.
500 – 1000 hrs
Table 17 Timing of Grease Supply
(Other than Long-life types)
Table 18 Timing of Grease Replacement
(Other than Long-life types)
COMMON
(5) Long-term stoppage
Table 15 Long-term stoppage