4
4-2 Installation angle
The installation angle shall be less than the limits shown in Fig.2.
4-1) Location of installation
Ambient temperature
: 0 to +40
(+32 to +104
Ambient humidity
: 85% max.
Ambient atmosphere
: There shall be no corrosive gas, explosive gas.
The installation space shall be well ventilated, and free from dust.
Location of installation : Indoors or outdoors.
. Special specifications are necessary when installation conditions are other than those mentioned here.
In such cases contact the nearest agent, dealer or service office.
. When a product is made according to special specifications for outdoor use or use in explosive
environments, the product can be safely operated under those specified conditions without problem.
Fig.2 Limits for installation angle
Table1 Torque of the installation bolts
Unit
SPA060
SPA070
SPA080
Bolt Size
−
M30
M36
Torque
N
・
m
1400
2430
Size
in
・lbs
12390
21510
. Install PARAMAX SINGLE STAGE DRIVE SPA Series on a sufficiently rigid base.
. Use installation bolts corresponding to JIS strength class 8.8 or its equivalent. The torque of installation bolts is
shown in table1.
5. Coupling with other machines
CAUTION
Install appropriate guard devices around rotating parts ; otherwise, injury may result.
When coupling PARAMAX SINGLE STAGE DRIVE SPA Series with a load, confirm that the alignment error is
within the specified limits shown in the maintenance manual, drawings, catalog, etc. ; otherwise, damage to
the system may result, due to misalignment.
Correctly tighten respective bolts to the specified torque shown in the drawing, catalog, etc. ; otherwise ;
scattering fragments may damage the system.
Remove the key temporarily attached to the output shaft of PARAMAX SINGLE STAGE DRIVE SPA Series when
the shaft is free-rotating (i. e. not loaded) ; otherwise, injury may result.
IF a backstop is installed in the reducer, verify that the applied motor rotation direction is correct.
Difference in the direction of rotation may cause injury or damage to the system.
C
C
F)
F
+1
°
0
+0.3
°
Summary of Contents for PARAMAX SPA Series
Page 14: ......