37
MAINTENANCE
6.6
OIL FILTER
The oil filter should be replaced after the first 50
hours of operation and then every 1,000 hours (or
quarterly) or if fault A:2020 or A:4807 is shown on
the microprocessor.
The fluid filter is located between the thermal valve
and the unit injection port. The SP models have
the filter mounted with the filter elements located
on the top side. Once the pressure in the system
has been completely depleted, most of if not all of
the fluid in the elements have drained out making
replacement simpler.
6.6.1 REMOVAL
1.
Follow
6.3 Stopping for Maintenance
procedures.
2.
Verify that compressor has little to no air
pressure prior to removal of component parts.
3.
A drain valve on side of head is supplied if
desired to drain residual fluid remaining in the
filter head.
4.
If at minimum, place a small pan under the
head, and with rag remove old element. A strap
wrench or equivalent may be needed to remove
the elements, discard the old elements in
accordance to local codes.
6.6.2 INSTALLATION
1.
Oil the gasket on the new oil filter.
2.
Attach new oil filter. Tighten by hand as much
as possible.
3.
Top off oil in sump tank and tighten oil fill cap.
4.
Start compressor and check for leaks around
the oil filter.
FIGURE 6-4.
1:1
SP20 ONLY
FLUID FILTER ELEMENT
REPLACEMENT FIGURE
1
2
3
5
A
B
C
D
E
F
5
4
3
2
1
F
E
D
C
B
A
4
B
DJW
FIRST USED ON:
3RD ANGLE
PROJECTION
1201 West US Highway 20, Michigan City IN 46360
1-800-438-6203
SHEET
SCALE:
TOLERANCES AS FOLLOWS:
REV
DESCRIPTION
THIS DRAWING AND ALL INFORMATION THEREIN IS THE PROPERTY OF SULLIVAN-PALATEK, INC. IS CONFIDENTIAL AND MUST NOT BE MADE PUBLIC OR COPIED.
WWW.SULLIVANPALATEK.COM
SULLIVAN-PALATEK
CHECKED BY:
DATE:
DATE:
DRAWN BY:
ANGLES: + OR - 1/2 DEG.
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE NOTED
X.XXX + OR - 0.005
X.XX + OR - 0.020
DECIMAL: X.X + OR - 0.050
MATERIAL:
IT IS LOANED SUBJECT TO RETURN UPON DEMAND, IS NOT TO BE USED DIRECTLY OR INDIRECTLY IN ANYWAY DETRIMENTAL TO SULLIVAN-PALATEK'S INTEREST.
DRAWING NO:
SIZE
1 OF 1
02/07/13
01
AS806-125250-RMT
FLPP 200-250HP RMT AC
DRAWING, ASSEMBLY
OIL FILTER MAINTENANCE