43
OPERATION
TABLE 5-1.
E/M CONTROLS COMPONENTS
ITEM
COMPONENT
DESCRIPTION
1
Oil Filter Differential
Displays pressure drop across the oil filter(s) for determining when to
maintenance
2
Separator Differential
Displays pressure drop across the separator element for determining
when to maintenance
3
Temperature
Displays temperature of air end oil leaving the air end for monitoring
4
Line Pressure
Displays the line pressure (air leaving the minimum pressure valve) for
monitoring
5
Sump Pressure
Displays pressure in the sump tank for monitoring
6
Power On Light
Amber light which turns on when power to the compressor is available
7
Selector Switch
3-position switch to select suitable mode of operation and to turn the
compressor off
8
Hour Meter
Records accumulated hours of compressor operation for planning and
logging service information
9
Start/Stop Button
ENCLOSED MACHINES ONLY. Red push button to start the compressor
(after selecting either AUTO or RUN mode on the selector switch) and
stop the compressor
5.2
MODES OF OPERATION
The selector switch allows the operator to choose between
RUN
and
AUTO
modes of operation for the
compressor. The functions of these modes are explained below.
5.2.1 RUN MODE
Selecting the
RUN
mode of operation will keep the motor running while the compressor is loaded and
unloaded. This mode of operation is best used in high air demand systems to minimize motor starts.
5.2.2 AUTO MODE
Selecting the
AUTO
mode of operation allows the motor to shut off during periods of little to no air usage, as
controlled by the pressure switch. The compressor will automatically restart once line pressure drops to the
load setting of the pressure switch.
5.3
PRIOR TO STARTING
5.3.1 PRIOR TO INITIAL START
»
Be familiar with the contents of this manual.
»
Be sure that all installation requirements have been met.
»
Inspect the compressor for any signs of visible damage that may have occurred during installation.
5.3.2 PRIOR TO EVERY START
»
Check fluid levels. Check that oil fill cap is tight.
»
Make sure the starter door is closed and latched.
WARNING!
Do not power up the compressor with the starter door open!
»
Check all pressure connections for tightness.
5.4
NORMAL START
1.
2.
Close main power disconnect.
3.
Turn the selector switch to either
RUN
or
AUTO
.
4.
For enclosed machines, push the
START/STOP
button on the front enclosure panel.
5.
Open the service valve to the plant air distribution system.
6.
Allow machine to reach normal operating pressure and observe operation of automatic controls.
7.
Check for any possible leaks.
Summary of Contents for 15D
Page 6: ...vi About This Manual ...
Page 12: ...4 Introduction ...
Page 20: ...12 Specifications 2 2 DIMENSIONS OPEN BASE MOUNT AIR COOLED Figure 2 1 GA 15 40D AC BM OPEN ...
Page 30: ...22 Specifications 2 12 PIPING AND INSTRUMENTATION AIR COOLED Figure 2 11 GA P I S R02 ...
Page 34: ...26 Specifications ...
Page 66: ...58 Troubleshooting ...
Page 112: ...NOTES ...
Page 113: ...NOTES ...