57
TROUBLESHOOTING
7.6
LINE PRESSURE RISES AbOVE UNLOAD PRESSURE
POSSIbLE CAUSE
REMEDY
Leak in control system tubing causing loss of
pressure signals
Replace tubing.
Defective solenoid valve
Repair or replace solenoid valve.
Faulty inlet valve
Repair or replace inlet valve.
7.7
EXCESSIVE LUbRICANT CONSUMPTION
POSSIbLE CAUSE
REMEDY
Clogged separator oil return line
Check for line blockage. Clean orifice and strainer located in oil
return sign glass assembly.
Separator element damaged or needs service
Change separator element.
Leak in lubrication system
Check all pipes, connections and components.
Operating pressure below 60 psig.
Repair minimum pressure valve.
7.8
PRESSURE RELIEF VALVE OPENS REPEATEDLY
POSSIbLE CAUSE
REMEDY
Incorrect control settings
Readjust .
Faulty pressure relief valve
Replace pressure relief valve.