Section 5
OPERATION
26
5.9 PURPOSE OF CONTROLS -- SUPERVISOR
II
(CONTINUED)
CONTROL OR INDICATOR
PURPOSE
FLUID PRESSURE---P3
Continually monitors injection fluid pressure and shuts
down the compressor in the event of low fluid pressure.
FLUID FILTER DIFFERENTIAL SWITCH
Continually monitors fluid filter differential and gener-
ates an alarm when the fluid filter needs replacement.
INLET FILTER MAINTENANCE SWITCH
Monitors condition of compressor inlet air filter and indi-
cates when replacement is required.
FLUID LEVEL SIGHT GLASS
Indicates fluid level in the sump. Proper level is not to
fall below the center of the sight glass. Check level
when compressor is shut down.
DO NOT OVERFILL.
COOLER BYPASS VALVE
Regulates flow of fluid to and around the cooler. De-
signed to maintain a minimum operating temperature of
180
_
F (82
_
C); used for fast warm---up on start---up.
MINIMUM PRESSURE/CHECK VALVE
Maintains minimum of 50 psig (3.4 bar) in the com-
pressor sump. Valve piston restricts receiver air dis-
charge from receiver/sump when pressure falls to 50
psig (3.4 bar). Also incorporated in this valve is a ter-
minal check valve which prevents line pressure back-
flow into the sump during unload conditions and after
shutdown.
PRESSURE RELIEF VALVE
Protects compressor by venting compressed air in
excess of 200 psig (13.8 bar) to atmosphere.
MODULATING INLET VALVE
Regulates the amount of air allowed to enter the air
compressor. This regulation is determined by the
amount of air being used at the service line. Also acts
as a check valve to prevent reverse compressor rota-
tion at shut down.
SOLENOID VALVE
Bypasses the pressure regulator valve causing the in-
let valve to close when the compressor reaches maxi-
mum operating pressure. Also activates blowdown
valve.
WATER REGULATING VALVE
Regulates the amount of cooling water used in the
(water---cooled only)
cooler to keep the compressor running at a normal op-
erating temperature of 170
_
F (77
_
C).
5.10 SUPERVISOR
II
OUTPUT RELAYS
RELAY
OPERATION
RUN RELAY (K1)
Contact closure energizes the compressor starter.
*---DELTA (K2)
A timed contact used to provide wye---delta transition
time.
UNLOAD/LOAD (K3)
Controls ON LOAD/OFF LOAD operation of the load
control solenoid valve.
COMMON FAULT (K4)
May be used to provide remote indication of any pre---
alarm, maintenance or fault shutdown condition.
DRAIN VALVE (K5)
Controls optional solenoid valve to provide automatic
condensate removal.
Summary of Contents for LS-10 18KW 24KT
Page 6: ...NOTES...
Page 15: ...Section 2 DESCRIPTION 9 Figure 2 3 Control System...
Page 18: ...12 NOTES...
Page 22: ...16 NOTES...
Page 26: ...20 NOTES...
Page 34: ...28 NOTES...
Page 38: ...32 NOTES...
Page 48: ...Section 7 MAINTENANCE 42 Figure 7 7 Piping and Instrumentation Diagram Standard...
Page 49: ...Section 7 MAINTENANCE 43 Figure 7 8 Piping and Instrumentation Diagram Supervisor II...
Page 50: ...44 NOTES...
Page 52: ...Section 8 ILLUSTRATIONS AND PARTS LIST 46 8 3 MOTOR COMPRESSOR FRAME AND PARTS...
Page 54: ...Section 8 ILLUSTRATIONS AND PARTS LIST 48 8 3 MOTOR COMPRESSOR FRAME AND PARTS...
Page 56: ...Section 8 ILLUSTRATIONS AND PARTS LIST 50 8 4 COOLER ASSEMBLY...
Page 58: ...Section 8 ILLUSTRATIONS AND PARTS LIST 52 8 5 AIR INLET SYSTEM...
Page 60: ...Section 8 ILLUSTRATIONS AND PARTS LIST 54 8 6 COOLING AND LUBRICATION SYSTEM...
Page 62: ...Section 8 ILLUSTRATIONS AND PARTS LIST 56 8 6 COOLING AND LUBRICATION SYSTEM...
Page 68: ...Section 8 ILLUSTRATIONS AND PARTS LIST 62 8 8 CONTROL SYSTEM AND ELECTRICAL PARTS...
Page 70: ...Section 8 ILLUSTRATIONS AND PARTS LIST 64 8 8 CONTROL SYSTEM AND ELECTRICAL PARTS...
Page 72: ...Section 8 ILLUSTRATIONS AND PARTS LIST 66 8 9 INSTRUMENT PANEL...
Page 76: ...Section 8 ILLUSTRATIONS AND PARTS LIST 70 8 11 DECAL GROUP 1 2 3 4 5 6 7 8 9 10 11...
Page 78: ...Section 8 ILLUSTRATIONS AND PARTS LIST 72 8 11 DECAL GROUP 12 13 14 15 16 17 18 19 20...
Page 80: ...Section 8 ILLUSTRATIONS AND PARTS LIST 74 8 11 DECAL GROUP 21 22 23 24 25 26 27...
Page 82: ...Section 8 ILLUSTRATIONS AND PARTS LIST 76 8 11 DECAL GROUP ADD FULL 29 28 30 31...
Page 88: ...NOTES...
Page 89: ...NOTES...