Section 5
OPERATION
18
5.2 PURPOSE OF CONTROLS
CONTROL OR INDICATOR
PURPOSE
PRESSURE RELIEF VALVE (Sump)
Opens sump pressure to the atmosphere should pres-
sure inside the sump become too high (375 PSIG
[2584kPa]).
PRESSURE RELIEF VALVE (Interstage)
Opens inner stage to atmosphere should the pressure
become too high (140 PSIG [965kPa]).
NOTE
Under certain conditions, it may be desirable to
pipe the relief valve to the outside of the building
for inside installation.
TERMINAL CHECK VALVE
Prevents line pressure backflow into the sump during
unload conditions and after shutdown.
SULLICON CONTROL
Regulates the amount of air allowed to enter the air in-
let valve. This regulation is determined by the amount
of air being used at the service line.
PILOT PRESSURE REGULATOR
Opens a pressure line between the sump and Sullicon
Control allowing the actuator to regulate air delivery to
air demand.
PILOT VALVE
Bypasses the pressure regulator valve causing the
Sullicon Control to close the inlet butterfly valve when
the compressor reaches maximum operating pres-
sure.
BLOWDOWN VALVE
Vents sump pressure to the atmosphere during unload
conditions and shutdown.
PRESSURE SWITCH
Senses service line pressure. When line pressure
reaches maximum operating pressure, the pressure
switch signals the pilot valve to unload the compressor.
MINIMUM PRESSURE/CHECK VALVE
Maintains a minimum pressure of 160 PSIG (1103kPa)
in the sump. This valve restricts air discharge from the
sump when the pressure falls to 160 PSIG (1103kPa).
However, full flow is allowed at normal operating pres-
sures.
HIGH DISCHARGE TEMPERATURE SWITCH
Shuts the compressor down if the discharge tempera-
ture from the first stage exceeds 265
_
F (130
_
C) or the
second stage exceeds 265
_
F (130
_
C).
LOW FLUID PRESSURE SWITCH
Shuts the compressor down if the fluid pressure down-
stream of the bearing filter drops below 90 PSIG
(621kPa).
INLET CYLINDER
Holds butterfly valve closed during start mode.
CLOSED INLET SOLENOID VALVE
Prevents the inlet cylinder from opening the inlet but-
terfly valve during start--up.
FLUID STOP VALVE PILOT VALVE
Vents the fluid stop valve pilot signal upon shutdown of
the compressor.
Summary of Contents for 20/12 500 CFM
Page 12: ...Section 2 DESCRIPTION 8 Figure 2 3 Piping and Instrumentation...
Page 14: ...Section 2 DESCRIPTION 10 Figure 2 5 Capacity Control System Typical...
Page 18: ...14 NOTES...
Page 20: ...16 NOTES...
Page 24: ...20 NOTES...
Page 38: ...34 NOTES...
Page 40: ...Section 7 ILLUSTRATIONS AND PARTS LIST 36 7 3 MOTOR FRAME COMPRESSOR AND PARTS...
Page 42: ...Section 7 ILLUSTRATIONS AND PARTS LIST 38 7 4 AIR INLET SYSTEM...
Page 44: ...Section 7 ILLUSTRATIONS AND PARTS LIST 40 7 5 COOLING AND LUBRICATION SYSTEM...
Page 46: ...Section 7 ILLUSTRATIONS AND PARTS LIST 42 7 6 COOLER ASSEMBLY...
Page 48: ...Section 7 ILLUSTRATIONS AND PARTS LIST 44 7 7 DISCHARGE SYSTEM...
Page 50: ...Section 7 ILLUSTRATIONS AND PARTS LIST 46 7 7 DISCHARGE SYSTEM...
Page 52: ...Section 7 ILLUSTRATIONS AND PARTS LIST 48 7 8 INSTRUMENT PANEL AND PARTS...
Page 54: ...Section 7 ILLUSTRATIONS AND PARTS LIST 50 7 9 CONTROL SYSTEM...
Page 56: ...Section 7 ILLUSTRATIONS AND PARTS LIST 52 7 9 CONTROL SYSTEM...
Page 58: ...Section 7 ILLUSTRATIONS AND PARTS LIST 54 7 10 ELECTRIC CONTROL BOX...
Page 60: ...Section 7 ILLUSTRATIONS AND PARTS LIST 56 7 11 UNIT TUBING...
Page 62: ...Section 7 ILLUSTRATIONS AND PARTS LIST 58 7 11 UNIT TUBING...
Page 64: ...Section 7 ILLUSTRATIONS AND PARTS LIST 60 7 12 DECAL GROUP...