Table7.2

 

Setting baud rate(2) 

Setting 

Baud rate 

Setting 

Baud rate 

Setting 

Baud rate 

Setting 

Baud rate 

S=97 

15463 

S=137 

10948 

S=177 

8474 

S=217 

6912 

S=98 

15306 

S=138 

10869 

S=178 

8426 

S=218 

6880 

S=99 

15151 

S=139 

10791 

S=179 

8379 

S=219 

6849 

S=100 

15000 

S=140 

10714 

S=180 

8333 

S=220 

6818 

S=101 

14851 

S=141 

10638 

S=181 

8287 

S=221 

6787 

S=102 

14705 

S=142 

10563 

S=182 

8241 

S=222 

6756 

S=103 

14563 

S=143 

10489 

S=183 

8196 

S=223 

6726 

S=104 

14423 

S=144 

10416 

S=184 

8152 

S=224 

6696 

S=105 

14285 

S=145 

10344 

S=185 

8108 

S=225 

6666 

S=106 

14150 

S=146 

10273 

S=186 

8064 

S=226 

6637 

S=107 

14018 

S=147 

10204 

S=187 

8021 

S=227 

6607 

S=108 

13888 

S=148 

10135 

S=188 

7978 

S=228 

6578 

S=109 

13761 

S=149 

10067 

S=189 

7936 

S=229 

6550 

S=110 

13636 

S=150 

10000 

S=190 

7894 

S=230 

6521 

S=111 

13513 

S=151 

9933 

S=191 

7853 

S=231 

6493 

S=112 

13392 

S=152 

9868 

S=192 

7812 

S=232 

6465 

S=113 

13274 

S=153 

9803 

S=193 

7772 

S=233 

6437 

S=114 

13157 

S=154 

9740 

S=194 

7731 

S=234 

6410 

S=115 

13043 

S=155 

9677 

S=195 

7692 

S=235 

6382 

S=116 

12931 

S=156 

9615 

S=196 

7653 

S=236 

6355 

S=117 

12820 

S=157 

9554 

S=197 

7614 

S=237 

6329 

S=118 

12711 

S=158 

9493 

S=198 

7575 

S=238 

6302 

S=119 

12605 

S=159 

9433 

S=199 

7537 

S=239 

6276 

S=120 

12500 

S=160 

9375 

S=200 

7500 

S=240 

6250 

S=121 

12396 

S=161 

9316 

S=201 

7462 

S=241 

6224 

S=122 

12295 

S=162 

9259 

S=202 

7425 

S=242 

6198 

S=123 

12195 

S=163 

9202 

S=203 

7389 

S=243 

6172 

S=124 

12096 

S=164 

9146 

S=204 

7352 

S=244 

6147 

S=125 

12000 

S=165 

9090 

S=205 

7317 

S=245 

6122 

S=126 

11904 

S=166 

9036 

S=206 

7281 

S=246 

6097 

S=127 

11811 

S=167 

8982 

S=207 

7246 

S=247 

6072 

S=128 

11718 

S=168 

8928 

S=208 

7211 

S=248 

6048 

S=129 

11627 

S=169 

8875 

S=209 

7177 

S=249 

6024 

S=130 

11538 

S=170 

8823 

S=210 

7142 

S=250 

6000 

S=131 

11450 

S=171 

8771 

S=211 

7109 

S=251 

5976 

S=132 

11363 

S=172 

8720 

S=212 

7075 

S=252 

5952 

S=133 

11278 

S=173 

8670 

S=213 

7042 

S=253 

5928 

S=134 

11194 

S=174 

8620 

S=214 

7009 

S=254 

5905 

S=135 

11111 

S=175 

8571 

S=215 

6976 

S=255 

5882 

S=136 

11029 

S=176 

8522 

S=216 

6944 

S=256 

5859 

unit

bps

 

 

 

Summary of Contents for EFP-LC

Page 1: ...nment MCU series name EFP LC Version RX66T series Ver 2 00 07 or later If your S W version of EFP LC is old one download the latest version data from the website below EFP LC latest S W free download...

Page 2: ...3 Connect EFP LC with target system Please connect EFP LC and the connection with the user target system using EF1TGCB X tip wire press cable or EF1TGCB B 4 wire type target connection cable to show...

Page 3: ...tput 14 Orange black dotted2 T_RESET 9 Connects to RESET pin 2 Output 16 Gray black dotted2 GND 10 Connects to VSS pin 3 Supplement of Pin Treatment 1 Supply VCC from user side to match source voltage...

Page 4: ...ecuting serial I O mode see Fig5 2 EFP LC side reset output is an open collector therefore connect to the RESET pin with 1k pull up resistor for open collector output If the reset circuit is CMOS outp...

Page 5: ...it Using Jumper 5 3 Handling of mode Pins For the RX66T series implement the terminal treatment of the mode terminal as shown in Table 5 1 When the handling of the Mode pins is not possible on a user...

Page 6: ...g verification I Setting and verification of ID code protection function 11 Erase E Flash ROM with built in MCU all areas are erased 12 Blank check B Check that the MCU built in ROM has been erased 13...

Page 7: ...ly command Format x 1 Description example x 1 Vdd is supplied to MCU Detail 1 VDD 5V is supplied to target MCU and access including data read verification writing in etc is enabled 2 In case power is...

Page 8: ...50000 S 26 57692 S 50 30000 S 74 20270 S 3 500000 S 27 55555 S 51 29411 S 75 20000 S 4 375000 S 28 53571 S 52 28846 S 76 19736 S 5 300000 S 29 51724 S 53 28301 S 77 19480 S 6 250000 S 30 50000 S 54 27...

Page 9: ...13 13274 S 153 9803 S 193 7772 S 233 6437 S 114 13157 S 154 9740 S 194 7731 S 234 6410 S 115 13043 S 155 9677 S 195 7692 S 235 6382 S 116 12931 S 156 9615 S 196 7653 S 236 6355 S 117 12820 S 157 9554...

Page 10: ...when this command is executed No 3 10 is displayed only when the setting is valid No 11 is displayed when MCU detailed information is set to 1 Table7 3 MCU information No Display location What to disp...

Page 11: ...r which ID code is not set 2 Verification of boot mode ID authentication code The MCU that has already set the ID code is compared with the ID authentication code 3 OCD ID code setting Set the ID code...

Page 12: ...rase erases the user area and data area The user boot area is not erased In one block erase only the specified block can be erased When erasing multiple consecutive blocks it is possible to batch eras...

Page 13: ...ail Checks that the MCU built in ROM within the specified range has been erased Note In the RX66T series execution units differ between the code flash area and data flash area Specify the start addres...

Page 14: ...in the EFP LC is 2 MB so when writing data of 2 MB or more split the Hxw file and save it An error will occur if an address outside the address range of the Hxw file is described in the start address...

Page 15: ...or will occur Since 0 is read from the area set as TM trusted memory a verification error will occur if the collation data is not 0 7 10 Read command Format R Hxw file name start address end address H...

Page 16: ...the thing to prevent the miss erase and miss writing Format K Lock block end address Set the lock bit of the specified one block K Lock block start address Lock block end address Set lock bits for mul...

Page 17: ...e lowercase Data type 0 input by ASCII codes 1 input by HEX codes Description example o c Execute configuration clear command o o 012345789ABCDEF 1 Set 0123567h to the OFS0 register Set 89ABCDEFh to t...

Page 18: ...tion ID code endian OFS and ROM code protection The configuration cannot be cleared unless all ROM data has been erased To execute the configuration clear execute the command in the following procedur...

Page 19: ...Block erase command prohibited Invalid Program command prohibited Invalid Read command prohibited Invalid ID authentication in serial programming mode Invalid Prohibit serial programmer connection In...

Page 20: ...d can be used any number of times in one PBT file Use example It is possible to operate the software for simple debugging or demonstration without disconnecting the cable for example when performing w...

Page 21: ...hxw FFF80000 FFFFFFFF 1 p Data_Program hxw 00100000 00107FFF 1 p Boot_Program hxw FF7F8000 FF7FFFFF 1 Verify check v User_Prog hxw FFF80000 FFFFFFFF v Data_Program hxw 00100000 00107FFF v Boot_Program...

Page 22: ...the data erased before blank command is executed In case it is erased with lock bit valid please try erasing it with lock bit invalid 4 In case of QzROM is it after read protect command is executed Th...

Page 23: ...About the poor contact If the connector or IC socket has poor contact it needs to be cleaned We recommend using a nanotech brush Kita Manufacturing Co Ltd for cleaning IC sockets Nanotech brushes can...

Page 24: ...24 24 EFP LC TypeE Supplementary manual For RX66T Revision history Revised version date Content 1st Edition April 3 2020 Create New...