10/24
)
EFP-LC TypeE Supplementary manual
(For RX66T)
7.4
Mode entry command
Execute a mode entry command and make each command feasible.
Record detailed MCU information in a log file.
Format :
M,OCO[,MCU detailed information]
MCU detailed information : Blank: No log output, 1: Log output
Description example
:
M,OCO
: No log output of MCU detailed information
M,OCO,1
: MCU detailed information log is output
Detail:
Firstly it is necessary to execute a mode entry command to execute a command in RX 66T series. Please fill in this
command after baud rate setting command. (S command)
Table7.3 shows the MCU information that can be referenced by this command.
No.1-2 is always displayed when this command is executed.
No.3-10 is displayed only when the setting is valid.
No.11 is displayed when MCU detailed information is set to “1”.
Table7.3
MCU information
No.
Display location
What to display
1
DEVICE NAME
MCU series name
2
ROM INFORMATION
ROM area, ROM size
3
OFS DATA Enabled!!
OFS0 / OFS1 register setting
4
READ Protected.
Read protection enabled
5
PROGRAM Protected.
Program protect is enabled
6
BLOCK ERASE Protected.
Block erase protect is enabled
7
TM SETTING Enabled.
Arbitrary code when setting TM area
8
SERIAL CONNECT Protected!!
Serial programmer connection prohibition
function is enabled
9
SERIAL AUTETICATION ID Enabled.
Boot mode ID authentication is enabled
10
OCD ID Enabled.
OCD ID is valid
11
ERASE BLOCK
Configuration of erase block
Note:
If boot mode ID authentication is set, MCU detailed information is output after the ID collation command.