Electric Connection
E
n
g
li
s
h
19
Heating Unit Pulstronic 2011 Mod. 313
must be fix installed and permanently exired.
Use distribution box of min IP 54.
Local national rules and regulations must be adhered to!
230 V ; 1~; max. 3,0 KW; according connection diagram, observe VDE 0100!
Only a specialist is authorized to install the unit.
Technical datas:
Security 250 °C opener/h
Temperature Control
Voltage supply 1x230 V +/-10% 50 Hz
Consumption approx. 2,5 VA
Output PWM 0-3000 W
Pump supply 230 V AC 2 Amp
eating
circuit (STB)
size l,w.h 495x385x200 mm
List on Determination of Number of Quantity of Drinking Bowls
Example:
* Theoretic peak values depend in practice of local circumstances and can result in lower values.
Spare Part List
22
Ref. Description
101.0308 Warning device
101.0309 Flow control ¾"
102.0732 flat seal (rubber dia.38x27x2) for brass screw
102.0769 brass reduction adapter 1¼” x ¾”
102.0780 brass non-return valve
102.0843 washer A 6,4 (M6) DIN 125
102.0844 hexagon nut self-locking M6 DIN 985
102.0846 half union in brass 1¼” x ¾” with seal
102.0847 ventilation screw
102.0876 brass vent valve (automatic)
102.0877 safety valve (automatic)
102.1349 locking screw threepart
102.1351 housing exit
102.1352 screwing bracket
102.1353 heating element
102.1359 screw M6x12 female hexagon
102.1361 o-ring dia. 62x5
102.1363 front housing
102.1372 non-return flap unit
102.1373 housing entry
102.1374 circulation pump with Flat seal (Ref. 102.0732)
102.1376 rear housing
102.1377 Mounting plate in plastic
102.1378 ¾” Closing Plug
102.1382 return flow temperature sensor
102.1383
S
ecurity
T
emperature Control (STB)
102.1386 forward flow temperature sensor
102.1395 Platine
102.1396 control unit with connection cable
Local circumstances:
4 bar of pressure, ¾" water line (150 l/min)
Question:
How many cattle-bowls can be connected in addition?
Calculation:
150 l/min : 12 l/min = 12,5 pieces
12,5 pieces x 2 (
experimental knowledge
) = 25 pieces
Answer:
25 pieces of CATTLE drinking bowls can be connected.
Summer 24 h-10 min run
dust/water protection IP 20
Connections 3 x 1,5 mm²
water pressure range 1 - 4 bar
water connection entry ¾”
water connection exit ¾”
weight 18,6 kg
21 l/min
16 l/min
12 l/min
6 l/min
½”
¾”
Flow rate of water
circuit
Mod.671 Mod.690
100 l/min
90 l/min
56 l/min
20 l/min
water flow
150 l/min 90 l/min
*
enquêtez à 4-5 bar
*
Mod.700 Cattle/Horses
drinking
bowls
44 l/min
36 l/min
25 l/min
9,6 l/min
1,3 l/min
1,1 l/min
0,9 l/min
0,7 l/min
Pig
drinking
bowls
12 l/min
11 l/min
8 l/min
4 l/min
Pressure
4 bar
3 bar
2 bar
1 bar
water flow
water flow
water flow
water flow
Water Flow Quantity depends on the following conditions:
Water pressure, length of pipes and cross sectional area as well as the quantity of diminutions
and curves.
Experimental knowledge
is based on field tests which revealed, however, that never all drinking
bowls are actuated at the same time.
This way the result /field test has to be multiplied with
factor two.
Heating Unit must be used in conjunction with a own residual
current device 230 V - 0,03 A !
A damaged heating or pump can cause that the residual current circuit breaker triggers and the
heating unit and pump is out of function. This leads to the possibility that the water supply line
risks to freeze given certain cold outside temperature.
Special and corresponding steps have to be taken at the spot by the user to protect it
against freezing:e.g. heating cables, warning system, etc.
101.0308
10
20
30
40
50
0
°C
101.0309
102.0877
102.0876
102.0780
102.1372
Accessories
102.1373
102.0769
102.0732
102.0846
102.1351
102.1352
102.1374
2x 102.1361
102.1359
102.1378
2x 102.1361
102.1359
102.0847
102.0732
102.1377
102.1352
102.1386
102.1382
102.1353
102.1383
S
T
B
102.1396
2
3
1
102.1376
102.1385
102.1395
102.1359
102.1363
lst
Pu
ronic
2011
102.1349
102.1359
102.0843
102.0844